Evidence map›Paper›PMID 37312138›Full record

SynthesisBMC surgery2023

Comparison of clinical outcomes of arthroscopic rotator cuff repair utilizing suture-bridge procedures with or without medial knots: a meta-analysis.

Qiu Huang, Xiaoyu Li, Ye Zhang, Changchun Jian, Hai Mou, Yunsheng Ou

Open access · goldAbstract readMeta-Analysis
In one paragraph

Synthesis in BMC surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Qiu HuangDepartment of Orthopedics, People's Hospital of Leshan, Shizhong District, Leshan, Sichuan, China.
Xiaoyu LiDepartment of Orthopedics, People's Hospital of Leshan, Shizhong District, Leshan, Sichuan, China.
Ye ZhangDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Changchun JianDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Hai MouDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Yunsheng OuDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China. ouyunsheng2001@163.com.
The Affiliated Yongchuan Hospital of Chongqing Medical University · CNSouthwest Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis investigation aimed to compare the medical efficacy of the knotted and knotless suture-bridge procedures in rotator cuff repair.

methodsThe Pubmed, Embase, and Cochrane Library datasets were searched for all available publications comparing the medical results of arthroscopic rotator cuff repairs utilizing knotted or knotless suture-bridge procedures. Two researchers utilized Newcastle-Ottawa Scale and Cochrane risk-of-bias tool to evaluate the included studies. Employing Revman 5.3 software, meta-analysis was conducted following the PRISMA reporting guideline.

resultsEleven investigations with 1083 patients were considered suitable for the final meta-analysis. 522 individuals were assigned to the knotted group, whereas 561 were assigned to the knotless group. No statistical difference was found between the knotted and knotless groups, regarding VAS score (WMD, 0.17; 95% CI, - 0.10 to 0.44; P = 0.21); Constant score (WMD, -1.50; 95% CI, - 3.52 to 0.52; P = 0.14); American Shoulder and Elbow Surgeons Shoulder (WMD, -2.02; 95% CI, - 4.53 to 0.49; P = 0.11); University of California Los Angeles score (WMD, -0.13; 95% CI, - 0.89 to 0.63; P = 0.73); ROM of flexion (WMD, 1.57; 95% CI, - 2.11 to 5.60; P = 0.37), abduction (WMD, 1.08; 95% CI, - 4.53 to 6.70; P = 0.71) and external rotation (WMD, 1.90; 95% CI, - 1.36 to 5.16; P = 0.25); re-tear rate (OR, 0.74; 95% CI, 0.50 to 1.08; P = 0.12), and medical complications (OR, 0.90; 95% CI, 0.37 to 2.20; P = 0.82).

conclusionFor arthroscopic rotator cuff repairs, there were no statistical differences in medical results among knotted and knotless suture-bridge procedures. Overall, both techniques showed excellent clinical outcomes and could be safely utilized to treat rotator cuff injuries.

Indexed as

Elbow JointLacerationsHumansNeurosurgical ProceduresRotator CuffSuturesKnotlessKnottedMeta-analysisRotator cuff repairSuture bridge