Evidence map›Paper›PMID 37311835›Full record

ArticleEye (London, England)2023

Performance of retinal fluid monitoring in OCT imaging by automated deep learning versus human expert grading in neovascular AMD.

Maximilian Pawloff, Bianca S Gerendas, Gabor Deak, Hrvoje Bogunovic, Anastasiia Gruber, Ursula Schmidt-Erfurth

Open access · hybridAbstract read
In one paragraph

Article in Eye (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
5.0field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Review
  12. A Novel Foundation Model-Based Framework for Multimodal Retinal Age Prediction.IEEE journal of translational engineering in health and medicine · 2025
    Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Maximilian PawloffDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria.ORCID 0000-0003-3168-5850
Bianca S GerendasDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria.ORCID 0000-0001-8940-8130
Gabor DeakDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-7885-7624
Hrvoje BogunovicDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-9168-0894
Anastasiia GruberDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Ursula Schmidt-ErfurthDepartment of Ophthalmology, Medical University of Vienna, Vienna, Austria. ursula.schmidt-erfurth@meduniwien.ac.at.ORCID 0000-0002-7788-7311
Medical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the reliability of automated fluid detection in identifying retinal fluid activity in OCT scans of patients treated with anti-VEGF therapy for neovascular age-related macular degeneration by correlating human expert and automated measurements with central retinal subfield thickness (CSFT) and fluid volume values.

methodsWe utilized an automated deep learning approach to quantify macular fluid in SD-OCT volumes (Cirrus, Spectralis, Topcon) from patients of HAWK and HARRIER Studies. Three-dimensional volumes for IRF and SRF were measured at baseline and under therapy in the central millimeter and compared to fluid gradings, CSFT and foveal centerpoint thickness (CPT) values measured by the Vienna Reading Center.

results41.906 SD-OCT volume scans were included into the analysis. Concordance between human expert grading and automated algorithm performance reached AUC values of 0.93/0.85 for IRF and 0.87 for SRF in HARRIER/HAWK in the central millimeter. IRF volumes showed a moderate correlation with CSFT at baseline (HAWK: r = 0.54; HARRIER: r = 0.62) and weaker correlation under therapy (HAWK: r = 0.44; HARRIER: r = 0.34). SRF and CSFT correlations were low at baseline (HAWK: r = 0.29; HARRIER: r = 0.22) and under therapy (HAWK: r = 0.38; HARRIER: r = 0.45). The residual standard error (IRF: 75.90 µm; SRF: 95.26 µm) and marginal residual standard deviations (IRF: 46.35 µm; SRF: 44.19 µm) of fluid volume were high compared to the range of CSFT values.

conclusionDeep learning-based segmentation of retinal fluid performs reliably on OCT images. CSFT values are weak indicators for fluid activity in nAMD. Automated quantification of fluid types, highlight the potential of deep learning-based approaches to objectively monitor anti-VEGF therapy.

Indexed as

Deep LearningWet Macular DegenerationAngiogenesis InhibitorsHumansIntravitreal InjectionsReproducibility of ResultsSubretinal FluidTomography, Optical CoherenceVascular Endothelial Growth Factor AVisual AcuityAngiogenesis InhibitorsVascular Endothelial Growth Factor A

Identifiers

PMID37311835
PMCPMC10698046
OpenAlexW4380483741

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.