Evidence map›Paper›PMID 37309134›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2025

A novel method for preparing clot analogs under dynamic vortical flow for testing mechanical thrombectomy devices.

Ronghui Liu, Bin Lv, Haoye Meng, Luo Zhang, Weijing Ma, Hongping He, Ren Wei, Na Ma, Yubo Fan, Jun Wang and 2 more

Open access · greenAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Ronghui LiuBeijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.ORCID 0000-0002-1550-8849
Bin LvDepartment of Neurology, the First Medical Center of Chinese PLA General Hospital, Beijing, China.
Haoye MengInstitute of Orthopedics, Chinese PLA General Hospital, Beijing Key Lab of Regenerative Medicine in Orthopedics, Key Laboratory of Musculoskeletal Trauma and War Injuries PLA, Beijing, China.
Luo ZhangKey Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Research Center for Biomedical Engineering, Medical Innovation & Research Division, Chinese PLA General Hospital, Beijing, China.
Weijing MaDepartment of Cardiovascular Surgery, Chinese PLA General Hospital, Beijing, China.
Hongping HeKey Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Research Center for Biomedical Engineering, Medical Innovation & Research Division, Chinese PLA General Hospital, Beijing, China.
Ren WeiDepartment of Vascular Surgery, Chinese PLA General Hospital, Beijing, China.
Na MaBeijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
Yubo FanBeijing Advanced Innovation Center for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
Jun WangDepartment of Neurology, the First Medical Center of Chinese PLA General Hospital, Beijing, China.
Xuewen RenDepartment of Emergency, the First Medical Center of Chinese PLA General Hospital, Beijing, China.
Weidong WangKey Laboratory of Biomedical Engineering and Translational Medicine, Ministry of Industry and Information Technology, Research Center for Biomedical Engineering, Medical Innovation & Research Division, Chinese PLA General Hospital, Beijing, China.
Chinese PLA General Hospital · CNBeihang University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundClot analogs are essential in animal and in vitro experiments on mechanical thrombectomy devices for treating acute ischemic stroke. Clot analogs should be capable of reproducing a variety of arterial clots observed in clinical practice in terms of histological composition and mechanical properties.MethodsBovine blood with added thrombin was stirred in a beaker so that clots could be formed under the condition of dynamic vortical flow. Static clots were also prepared without stirring, and the properties of the static clots and dynamic clots were compared. Histological and scanning electron microscopy experiments were performed. Compression and relaxation tests were performed to evaluate the mechanical properties of the two types of clots. Thromboembolism and thrombectomy tests were conducted in an in vitro circulation model.ResultsCompared to the static clots, the dynamic clots prepared under vortical flow displayed a higher fibrin content, and their fibrin network was denser and sturdier than that of the static clots. The stiffness of the dynamic clots was significantly higher than that of the static clots. The stress of both types of clots could decay quickly under large sustained strain. The static clots could break at the bifurcation in the vascular model, while the dynamic clots could be firmly stuck in the vascular model.ConclusionsDynamic clots generated in dynamic vortical flow differ significantly from static clots in terms of their composition and mechanical properties, which may be beneficial information for preclinical research on mechanical thrombectomy devices.

Indexed as

Mechanical ThrombolysisThrombectomyThrombosisAnimalsHumansMicroscopy, Electron, ScanningStress, Mechanicalacute ischemic strokeClot analogsin vitro modelmechanical thrombectomy

Identifiers

PMID37309134
PMCPMC12475351
OpenAlexW4380422948

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.