ArticleBMC ophthalmology2023
Donor lamella thickness after ultrathin Descemet stripping automated endothelial keratoplasty and its relation to postoperative visual acuity and pre-operative lamella measures.
Article in BMC ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo accurately measure ultrathin Descemet stripping automated endothelial keratoplasty (DSAEK) donor lamella thickness during the first postoperative year and to correlate this with pre-operative and other postoperative measurements.
methodsDonor lamella thickness in 41 eyes undergoing DSAEK for Fuchs endothelial dystrophy (FED) was measured using the Tomey Casia OCT directly after graft preparation and at 1 week and 1, 3, 6 and 12 months postoperatively. Visual acuity and endothelial cell density were measured as the secondary parameters.
resultsIndividual graft thickness profiles were shown to be fairly regular within the optically relevant area. There was a strong and highly significant correlation between the pre- and postoperative lamellar thicknesses at all time points (p < 0.0001). Compared with the measurements directly after preparation at the cornea bank, the lamella thickness decreased by 12% after 12 months. Between 1 and 12 months postoperatively, the lamella thickness (mean ± SD) changed from 112 ± 27 μm to 101 ± 21 μm. Best spectacle-corrected visual acuity (BSCVA) changed from 0.46 ± 0.30 logMAR pre-operatively through 0.36 ± 0.33 at 1 month to 0.13 ± 0.16 at 1 year postoperatively. The endothelial cell counts were comparable to those reported in previous studies.
conclusionsThickness profiles of individual grafts were fairly regular within the optically relevant area. A strong relationship between pre- and postoperative graft thicknesses was detected, and ultrathin DSAEK grafts prepared using methods similar to that applied in this study are expected to show a deswelling of around 12% during the first postoperative year. No correlation was detected between graft thickness and BSCVA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.