Evidence map›Paper›PMID 37307872›Full record

ArticleBrain stimulation

A novel whole-head RF coil design tailored for concurrent multichannel brain stimulation and imaging at 3T.

Lucia I Navarro de Lara, Jason P Stockmann, Qinglei Meng, Boris Keil, Azma Mareyam, Işıl Uluç, Mohammad Daneshzand, Sergey Makarov, Lawrence L Wald, Aapo Nummenmaa

Abstract read
In one paragraph

Article in Brain stimulation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Multi-coil TMS for preclinical applications in ultra-high-field MRI.Imaging neuroscience (Cambridge, Mass.) · 2025
    Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Lucia I Navarro de LaraAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA. Electronic address: lnavarrodelara@mgh.harvard.edu.
Jason P StockmannAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.
Qinglei MengAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.
Boris KeilInstitute of Medical Physics and Radiation Protection, Department of Life Science Engineering, TH Mittelhessen University of Applied Sciences, Giessen, Germany; Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Phillipps University of Marburg, Marburg, Germany.
Azma MareyamAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA.
Işıl UluçAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.
Mohammad DaneshzandAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.
Sergey MakarovAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA; Department of Electrical and Computer Engineering at the Worcester Polytechnic Institute, Worcester, MA, 01609, USA.
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.
Aapo NummenmaaAthinoula A. Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, 02129, USA; Harvard Medical School, Boston, MA, 02115, USA.

Funding

Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Lawrence L Wald · 2020 to 2026
$10.9M
Integrated multichannel system for transcranial magnetic stimulation and parallel magnetic resonance imagingR01MH111829 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI NUMMENMAA, AAPO · 2016 to 2019
$3.2M
MRI technology for restoring brain image quality for pediatric patients with metallic orthodontic hardwareR01EB028797 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Berkin Bilgic, Jason P Stockmann · 2020 to 2026
$3.0M
Decoding parametric attributes of auditory working memories from human brain activityR01DC016915 · NIDCD · MASSACHUSETTS GENERAL HOSPITAL · PI AHVENINEN, JYRKI · 2018 to 2022
$3.0M
Collaborative robot (cobot) controlled system for transcranial magnetic stimulationS10OD028668 · OD · MASSACHUSETTS GENERAL HOSPITAL · PI NUMMENMAA, AAPO · 2021 to 2021
$558k
Wearable RF-EEG Cap for closed loopTMS/fMRI/EEG ApplicationsK99EB032749 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI NAVARRO DE LARA, LUCIA ISABEL · 2022 to 2023
$381k
NIBIB NIH HHS K99 EB032749NIBIB NIH HHS P41 EB030006NIBIB NIH HHS R01 EB028797NIDCD NIH HHS R01 DC016915NIH HHS S10 OD028668NIMH NIH HHS R01 MH111829
6 · The paper itself

Abstract

purposeMultichannel Transcranial Magnetic Stimulation (mTMS) [1] is a novel non-invasive brain stimulation technique allowing multiple sites to be stimulated simultaneously or sequentially under electronic control without movement of the coils. To enable simultaneous mTMS and MR imaging, we have designed and constructed a whole-head 28-channel receive-only RF coil at 3T.

methodsA helmet-shaped structure was designed considering a specific layout for a mTMS system with holes for positioning the TMS units next to the scalp. Diameter of the TMS units defined the diameter of RF loops. The placement of the preamplifiers was designed to minimize possible interactions and to allow straightforward positioning of the mTMS units around the RF coil. Interactions between TMS-MRI were analyzed for the whole-head system extending the results presented in previous publications [2]. Both SNR- and g-factors maps were obtained to compare the imaging performance of the coil with commercial head coils.

resultsSensitivity losses for the RF elements containing TMS units show a well-defined spatial pattern. Simulations indicate that the losses are predominantly caused by eddy currents on the coil wire windings. The average SNR performance of the TMSMR 28-channel coil is about 66% and 86% of the SNR of the 32/20-channel head coil respectively. The g-factor values of the TMSMR 28-channel coil are similar to the 32-channel coil and significantly better than the 20-channel coil.

conclusionWe present the TMSMR 28-channel coil, a head RF coil array to be integrated with a multichannel 3-axisTMS coil system, a novel tool that will enable causal mapping of human brain function.

Indexed as

BrainTranscranial Magnetic StimulationEquipment DesignHumansMagnetic Resonance ImagingPhantoms, ImagingScalpStereotaxic TechniquesMTMSNon-invasive brain stimulationSimultaneous TMS/fMRIWhole-head RF coil

Identifiers

PMID37307872
PMCPMC10499022

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.