Evidence map›Paper›PMID 37305197›Full record

ArticlePlastic and reconstructive surgery. Global open2023

Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review.

Chatchai Pruksapong, Suttisun Jankajorn, Chairat Burusapat, Nutthapong Wanichjaroen, Nuttadon Wongprakob, Peeraya Techasatian

Open access · goldAbstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Chatchai PruksapongDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Suttisun JankajornDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Chairat BurusapatDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Nutthapong WanichjaroenDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Nuttadon WongprakobDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Peeraya TechasatianDivision of Plastic and Reconstructive Surgery, Department of Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Creative Commons · USPhramongkutklao Hospital · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Upper eyelid blepharoplasty is a popular aesthetic surgery. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types. We aimed to compare the Colorado needle electrocautery pure cutting mode and the traditional scalpel to determine their efficacy, complications, and cosmetic outcomes. Methods: A systematic review was performed to review the outcome with the conventional method (scalpel) and other methods in upper blepharoplasty procedures. Further, a prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and the scalpel in upper blepharoplasty. Study outcomes included scar quality at different times until 1-year postoperation, bleeding during incision, and postoperative ecchymosis. Results: Five articles met the inclusion criteria for this systematic review. The prospective randomized controlled trial study included 30 patients; the average incisional time on the electrocautery side was significantly longer than that on the scalpel side, and the electrocautery side had less blood loss during incision than the scalpel side (2.4 versus 3.27 using average cotton bud sticks, respectively) ( Conclusions: Colorado needle electrocautery pure cutting mode can be an alternative to traditional scalpel for upper eyelid blepharoplasty skin incision because of long-term scar quality. Electrocautery use has hemostatic benefits, leading to a decrease in bleeding that can obscure the incision site. However, the incision time on the electrocautery side was significantly longer than the scalpel side, which may be owing to an adaptation of surgical technique.

Identifiers

PMID37305197
PMCPMC10256415
OpenAlexW4380089307

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.