Evidence map›Paper›PMID 37304828›Full record

ArticleFrontiers in physiology2023

Full-scale numerical simulation of hemodynamics based on left ventricular assist device.

Xinyi Gao, Zhike Xu, Chenghan Chen, Pengfei Hao, Feng He, Xiwen Zhang

Open access · goldAbstract read
In one paragraph

Article in Frontiers in physiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Xinyi GaoApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Zhike XuApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Chenghan ChenApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Pengfei HaoApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Feng HeApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Xiwen ZhangApplied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Tsinghua University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ventricular assist devices have been widely used and accepted to treat patients with end-stage heart failure. The role of VAD is to improve circulatory dysfunction or temporarily maintain the circulatory status of patients. In order to be closer to the medical practice, a multi-Domain model of the left ventricular coupled axial flow artificial heart was considered to study the effect of its hemodynamics on the aorta. Because whether LVAD itself was connected between the left ventricular apex and the ascending aorta by catheter in the loop was not very important for the analysis of simulation results, on the premise of ensuring the multi-Domain simulation, the simulation data of the import and export ends of LVAD were imported to simplify the model. In this paper, the hemodynamic parameters in the ascending aorta, such as blood flow velocity vector, wall shear stress distribution, vorticity current intensity, vorticity flow generation, etc., have been calculated. The numerical conclusion of this study showed the vorticity intensity under LVAD was significantly higher than that under patients' conditions and the overall condition is similar to that of a healthy ventricular spin, which can improve heart failure patients' condition while minimizing other pitfalls. In addition, high velocity blood flow during left ventricular assist surgery is mainly concentrated near the lining of the ascending aorta lumen. What's more, the paper proposes to use Q criterion to determine the generation of vorticity flow. The Q criterion of LVAD is much higher than that of patients with heart failure, and the closer the LVAD is to the wall of the ascending aorta, the greater the Q criterion is. All these are beneficial to the effectiveness of LVAD in the treatment of heart failure patients and provide clinical suggestions for the LVAD implantation in clinical practice.

Indexed as

aortaCFDfull-scale modelheart failurehemodynamicsLVAD

Identifiers

PMID37304828
PMCPMC10248007
OpenAlexW4378232495

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.