ArticleJournal of medical imaging (Bellingham, Wash.)2023

Image quality and radiation dose in spinal surgery: a comparison of three imaging systems in phantom.

Margherita Casiraghi, Maria Antonietta Piliero, Luca Bellesi, Mathieu Dufour, Anindita Chatterjea, Pietro Scarone, Stefano Presilla

Open access · greenAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Margherita CasiraghiImaging Institute of Southern Switzerland, Medical Physics Division, Bellinzona, Switzerland.ORCID https://orcid.org/0000-0002-6715-6849
Maria Antonietta PilieroImaging Institute of Southern Switzerland, Medical Physics Division, Bellinzona, Switzerland.
Luca BellesiImaging Institute of Southern Switzerland, Medical Physics Division, Bellinzona, Switzerland.
Mathieu DufourImaging Institute of Southern Switzerland, Medical Physics Division, Bellinzona, Switzerland.
Anindita ChatterjeaPhilips Healthcare, Image Guided Therapy Systems, Best, The Netherlands.
Pietro ScaroneNeurocenter of Southern Switzerland, Neurosurgical Service, Lugano, Switzerland.
Stefano PresillaImaging Institute of Southern Switzerland, Medical Physics Division, Bellinzona, Switzerland.
Istituto Imaging della Svizzera ItalianaInstitute of Oncology Research · CHLaboratory for Biomedical Neurosciences · CHPhilips (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Using optimal settings for x-ray scans is crucial for obtaining three-dimensional images of high quality while keeping the patient dose low. Our work compares dose and image quality (IQ) of three intraoperative imaging systems [O-arm cone-beam computed tomography (CBCT), ClarifEye C-arm CBCT, and Airo computed tomography] used for spinal surgery. Approach: Patients of 70, 90, and 110 kg were simulated with an anthropomorphic phantom by adding tissue-equivalent material. Titanium inserts were placed in the phantom spine for reproducing metal artifacts in the images. Organ dose was measured with thermo-luminescent dosimeters for effective dose ( Results: The ClarifEye protocols resulted in the lowest Conclusions: Both CBCT systems provided better IQ compared with Airo for navigation of lumbar spinal surgery for the original phantom. Metal artifacts particularly affect O-arm images decreasing the subjective IQ. The high spatial resolution of CBCT systems resulted in a relevant parameter for the visibility of anatomical features important for spine navigation. Low dose protocols were enough to obtain a clinically acceptable contrast-to-noise ratio in the bones.

Indexed as

computed tomographycone-beam computed tomographyeffective doseimage qualityintraoperative imagingspinal surgery

Identifiers

PMID37304527
PMCPMC10251430
OpenAlexW4379985221

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.