Evidence map›Paper›PMID 37303854›Full record

ArticleResuscitation plus2023

The impact of a ventilation timing light on CPR Quality: A randomized crossover study.

Ben Jones, Stephen Aiello, Kevin Govender, Brayden Shaw, Bruce Tseng, Zaid Dawad, Mel McAulay, Norm Wilkinson

Open access · goldAbstract read
In one paragraph

Article in Resuscitation plus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Ben JonesParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Stephen AielloParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Kevin GovenderParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Brayden ShawParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Bruce TsengParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Zaid DawadParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Mel McAulayParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Norm WilkinsonParamedicine Department, Auckland University of Technology, Auckland, New Zealand.
Auckland University of Technology · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A ventilation timing light (VTL) is a small commercially available single-use device that is programmed to light up at six-second intervals prompting rescuers to provide a single controlled breath during manual ventilation. The device also indicates the duration of the breath by remaining illuminated for the duration of the inspiratory time. The aim of this study was to evaluate the impact of the VTL on a selection of CPR quality metrics. Methods: A total of 71 paramedic students who were already proficient in performing high-performance CPR (HPCPR) were required to perform HPCPR with and without a VTL. The quality of the HPCPR delivered, reflected by the selected quality metrics; chest compression fraction (CCF), chest compression rate (CCR), and ventilation rate (VR), was then evaluated. Results: While HPCPR with and without a VTL were both able to achieve guideline-based performance targets of CCF, CCR, and VR, the group who had used the VTL to deliver HPCPR were able to consistently provide 10 ventilations for every minute of asynchronous compressions (10 breath/min vs 8.7 breath/min Conclusion: The use of a VTL allows for a VR target of 10 ventilations per minute to be consistently achieved without compromising guideline-based compression fraction targets (>80%), and chest compression rates when used during the delivery of HPCPR in a simulated OHCA event.

Indexed as

CPR qualityEMSHPCPROHCAParamedicVentilationVentilation timing light

Identifiers

PMID37303854
PMCPMC10248546
OpenAlexW4379184876

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.