Evidence map›Paper›PMID 37303455›Full record

ArticleCureus2023

The Incidence of Optic Cracks or Fractures During a Foldable AcrySof or Acriva BB Acrylic Monofocal Intraocular Lens Implantation via the Manual Monarch Injector System With the Cartridge in Phacoemulsification Surgery.

Cem Evereklioglu, Yusuf Uysal, Hidayet Sener, Hatice Kübra Sönmez, Fatih Horozoglu

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Cem EverekliogluDepartment of Ophthalmology, Erciyes University Medical Faculty, Kayseri, TUR.
Yusuf UysalDepartment of Ophthalmology, Gulhane Training and Research Hospital, Ankara, TUR.
Hidayet SenerDepartment of Ophthalmology, Erciyes University Medical Faculty, Kayseri, TUR.
Hatice Kübra SönmezDepartment of Ophthalmology, Erciyes University Medical Faculty, Kayseri, TUR.
Fatih HorozogluDepartment of Ophthalmology, Erciyes University Medical Faculty, Kayseri, TUR.
Gülhane Askerî Tıp Akademisi · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the incidence of optic cracks and/or fractures during foldable acrylic intraocular lens (IOL) implantation via the manual Monarch delivery system with the cartridge and to determine factors that help to avoid such complications.

methodsSmall-incision phacoemulsification surgery was performed in 702 eyes with visually significant cataract formation. A foldable acrylic soft IOL (AcrySof

resultsPostoperative central, paracentral, or peripheral optic cracks or fractures were encountered in a total of six of 702 eyes (0.85%). Four of six lenses (0.57%) had optic cracks within the IOL substance, whereas two of 702 cases (0.28%) had full-thickness IOL fractures in the substance in multiple locations. Three of the four lenses with optic cracks were noted to be handled by tying forceps during the cartridge insertion, and one of them was the complication of holding forceps. Two IOLs with full-thickness optic fractures were encountered during the insertion of the IOLs in the capsular bag as a result of direct trauma to the lens optic by the plunger of the injector system overriding the lens optic during cartridge passage. None of the patients suffered from glare or other visual disturbances postoperatively, and, therefore, none of the six eyes required lens replacement.

conclusionThe unintentional extensive pressure effect of the forceps during the holding process of the IOL or the direct trauma to the lens optic by the plunger of injector systems may cause optic cracks or fractures. Physicians should continue to monitor the eyes postoperatively regularly and must determine the benefits and risks to be derived from lens replacement, if such patients complain of significant glare, image degradation, and visual disturbances. We recommend the use of preloaded lenses, which have their own delivery systems and cartridges, to minimize the risk of such complications.

Indexed as

crackfoldablefractureglareintraocular lensmonofocaltying forceps

Identifiers

PMID37303455
PMCPMC10257524
OpenAlexW4376127690

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.