Formaldehyde Reduction in an Operating Room Setting: Comparison of a Catalytic Surgical Vacuum Device With a Traditional Smoke Evacuator.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Electrosurgery exposes healthcare workers to volatile organic compounds (VOCs) including formaldehyde. Adopting electrosurgical devices that catalytically transform formaldehyde to benign substances has the potential to improve safety in surgical settings. Materials and methods We compared the efficiency of formaldehyde removal of two medical devices. The first was a novel surgical vacuum (SV) device containing ultra-low particulate air (ULPA) filtration, activated carbon and catalytic transition metal oxide. The second was a commonly utilized handpiece evacuator (HE) that contained only mechanical filtration and activated carbon granules. Both devices were exposed to formalin vapor. Results The time weighted average (TWA), median and peak concentrations of detected formaldehyde at the outflow of the SV unit were 90% lower than the corresponding values detected at the outflow of the HE device (p = 0.0034). When catalytic material was added to the HE device, the detected formaldehyde concentration at the outflow was reduced by 55% (p = 2.9 x 10