ArticleLung2023
Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure.
Article in Lung, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- A temporal deep learning algorithm for prediction of extubation failures in critical care patients.Journal of clinical monitoring and computing · 2026Article
- Observational
- Value of combining lung ultrasound score with oxygenation and functional indices in determining weaning timing for critically ill pediatric patients.BMC medical imaging · 2025Article
- Predictors of weaning failure in ventilated intensive care patients: a systematic evidence map.Critical care (London, England) · 2024Review
- LUNG Year in Review: 2023.Lung · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeVentilator weaning protocols rely in part on objective indices to best predict extubation failure in the critically ill. We investigated static respiratory system compliance (RC) as a predictor of extubation failure, in comparison to extubation readiness using rapid shallow breathing index (RSBI). MATERIAL AND
methodsThis was a cross-sectional, multi-institutional study of mechanically ventilated patients admitted between 12/01/2017 and 12/01/2019. All patients older than 18 years with a documented spontaneous breathing trial and extubation trial were included. RC and RSBI were calculated prior to the extubation trial. The primary outcome was extubation failure-defined as need for reintubation within 72 h from time of extubation.
resultsOf the 2263 patients, 55.8% were males with a mean age of 68 years. The population consisted mostly of Caucasians (73%) and African Americans (20.4%). 274 (12.1%) patients required reintubation within 72 h. On multivariate logistic regression after adjusting for age, sex, body mass index (BMI), admission Sequential Organ Failure Assessment (SOFA) score, number of ventilator days, and the P/F ratio on the day of extubation, RC remained the strongest predictor for extubation failure at 24 h (aOR 1.45; 95% CI 1.00-2.10) and 72 h (aOR 1.58; 95% CI 1.15-2.17). There was no significant association between RSBI and extubation failure at 24 (aOR 1.00; 95% CI 0.99-1.01) or at 72 h (aOR 1.00; 95% CI 0.99-1.01).
conclusionRC measured on the day of extubation is a promising physiological discriminant to potentially risk stratify patients with acute respiratory failure for extubation readiness. We recommend further validation studies in prospective cohorts.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials