Evidence map›Paper›PMID 37300053›Full record

ArticleSensors (Basel, Switzerland)2023

A Spectroscopic Reflectance-Based Low-Cost Thickness Measurement System for Thin Films: Development and Testing.

Néstor Eduardo Sánchez-Arriaga, Divya Tiwari, Windo Hutabarat, Adrian Leyland, Ashutosh Tiwari

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Néstor Eduardo Sánchez-ArriagaAmy Johnson Building, Department of Automatic Control and Systems Engineering, University of Sheffield, Portobello St., Sheffield S1 3JD, UK.ORCID 0000-0002-3251-4116
Divya TiwariAmy Johnson Building, Department of Automatic Control and Systems Engineering, University of Sheffield, Portobello St., Sheffield S1 3JD, UK.
Windo HutabaratAmy Johnson Building, Department of Automatic Control and Systems Engineering, University of Sheffield, Portobello St., Sheffield S1 3JD, UK.
Adrian LeylandSir Robert Hadfield Building, Department of Materials Science and Engineering, University of Sheffield, Mappin St., Sheffield S1 3JD, UK.
Ashutosh TiwariAmy Johnson Building, Department of Automatic Control and Systems Engineering, University of Sheffield, Portobello St., Sheffield S1 3JD, UK.
University of Sheffield · GB

Funding

CONACYT 1059795Engineering and Physical Sciences Research Council EP/S036180/1Engineering and Physical Sciences Research Council EP/T024607/1
6 · The paper itself

Abstract

The requirement for alternatives in roll-to-roll (R2R) processing to expand thin film inspection in wider substrates at lower costs and reduced dimensions, and the need to enable newer control feedback options for these types of processes, represents an opportunity to explore the applicability of newer reduced-size spectrometers sensors. This paper presents the hardware and software development of a novel low-cost spectroscopic reflectance system using two state-of-the-art sensors for thin film thickness measurements. The parameters to enable the thin film measurements using the proposed system are the light intensity for two LEDs, the microprocessor integration time for both sensors and the distance from the thin film standard to the device light channel slit for reflectance calculations. The proposed system can deliver better-fit errors compared with a HAL/DEUT light source using two methods: curve fitting and interference interval. By enabling the curve fitting method, the lowest root mean squared error (RMSE) obtained for the best combination of components was 0.022 and the lowest normalised mean squared error (MSE) was 0.054. The interference interval method showed an error of 0.09 when comparing the measured with the expected modelled value. The proof of concept in this research work enables the expansion of multi-sensor arrays for thin film thickness measurements and the potential application in moving environments.

Indexed as

ArduinomicroprocessorPythonreflectometrysensorthickness measurementsthin film

Identifiers

PMID37300053
PMCPMC10256034
OpenAlexW4379470898

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.