Evidence map›Paper›PMID 37299961›Full record

ArticleSensors (Basel, Switzerland)2023

Estimating Thoracic Movement with High-Sampling Rate THz Technology.

Christoph Hoog Antink, Romina Schulz, Maurice Rohr, Konstantin Wenzel, Lars Liebermeister, Robert Kohlhaas, Sascha Preu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christoph Hoog AntinkKIS*MED (AI Systems in Medicine Lab), Technische Universität Darmstadt, 64283 Darmstadt, Germany.ORCID 0000-0001-7948-8181
Romina SchulzTerahertz Devices and Systems, Technische Universität Darmstadt, 64283 Darmstadt, Germany.
Maurice RohrKIS*MED (AI Systems in Medicine Lab), Technische Universität Darmstadt, 64283 Darmstadt, Germany.ORCID 0000-0002-6053-6558
Konstantin WenzelFraunhofer Institute for Telecommunications, Heinrich Hertz Institute, 10587 Berlin, Germany.ORCID 0009-0000-7145-7874
Lars LiebermeisterFraunhofer Institute for Telecommunications, Heinrich Hertz Institute, 10587 Berlin, Germany.ORCID 0000-0001-9415-5051
Robert KohlhaasFraunhofer Institute for Telecommunications, Heinrich Hertz Institute, 10587 Berlin, Germany.ORCID 0000-0003-4765-1954
Sascha PreuTerahertz Devices and Systems, Technische Universität Darmstadt, 64283 Darmstadt, Germany.ORCID 0000-0003-0818-1865

Funding

Deutsche Forschungsgemeinschaft SFB-TRR 196 "MARIE"
6 · The paper itself

Abstract

We use a high-sampling rate terahertz (THz) homodyne spectroscopy system to estimate thoracic movement from healthy subjects performing breathing at different frequencies. The THz system provides both the amplitude and phase of the THz wave. From the raw phase information, a motion signal is estimated. An electrocardiogram (ECG) signal is recorded with a polar chest strap to obtain ECG-derived respiration information. While the ECG showed sub-optimal performance for the purpose and only provided usable information for some subjects, the signal derived from the THz system showed good agreement with the measurement protocol. Over all the subjects, a root mean square estimation error of 1.40 BPM is obtained.

Indexed as

RespirationTerahertz SpectroscopyElectrocardiographyHumansMovementTechnologyphotonicrespiratory rateterahertzunobtrusive sensing

Identifiers

PMID37299961
PMCPMC10256075

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.