Evidence map›Paper›PMID 37299955›Full record

ArticleSensors (Basel, Switzerland)2023

An Integrated, Exchangeable Three-Electrode Electrochemical Setup for AFM-Based Scanning Electrochemical Microscopy.

Andreas Karg, Sebastian Gödrich, Philipp Dennstedt, Nicolas Helfricht, Markus Retsch, Georg Papastavrou

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Andreas KargPhysical Chemistry II, University of Bayreuth, 95447 Bayreuth, Germany.
Sebastian GödrichPhysical Chemistry II, University of Bayreuth, 95447 Bayreuth, Germany.
Philipp DennstedtPhysical Chemistry II, University of Bayreuth, 95447 Bayreuth, Germany.
Nicolas HelfrichtPhysical Chemistry II, University of Bayreuth, 95447 Bayreuth, Germany.ORCID 0000-0002-5839-9670
Markus RetschBavarian Institute for Battery Technology, University of Bayreuth, 95448 Bayreuth, Germany.ORCID 0000-0003-2629-8450
Georg PapastavrouPhysical Chemistry II, University of Bayreuth, 95447 Bayreuth, Germany.
University of Bayreuth · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Scanning electrochemical microscopy (SECM) is a versatile scanning probe technique that allows monitoring of a plethora of electrochemical reactions on a highly resolved local scale. SECM in combination with atomic force microscopy (AFM) is particularly well suited to acquire electrochemical data correlated to sample topography, elasticity, and adhesion, respectively. The resolution achievable in SECM depends critically on the properties of the probe acting as an electrochemical sensor, i.e., the working electrode, which is scanned over the sample. Hence, the development of SECM probes received much attention in recent years. However, for the operation and performance of SECM, the fluid cell and the three-electrode setup are also of paramount importance. These two aspects received much less attention so far. Here, we present a novel approach to the universal implementation of a three-electrode setup for SECM in practically any fluid cell. The integration of all three electrodes (working, counter, and reference) near the cantilever provides many advantages, such as the usage of conventional AFM fluid cells also for SECM or enables the measurement in liquid drops. Moreover, the other electrodes become easily exchangeable as they are combined with the cantilever substrate. Thereby, the handling is improved significantly. We demonstrated that high-resolution SECM, i.e., resolving features smaller than 250 nm in the electrochemical signal, could be achieved with the new setup and that the electrochemical performance was equivalent to the one obtained with macroscopic electrodes.

Indexed as

Microscopy, Atomic ForceElectrodesMicroscopy, Electrochemical, Scanningatomic force microscopyelectrochemical sensorsscanning electrochemical microscopy

Identifiers

PMID37299955
PMCPMC10255986
OpenAlexW4378983172

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.