Evidence map›Paper›PMID 37299920›Full record

ArticleSensors (Basel, Switzerland)2023

A Microstrip Transmission Line Biosensor to Measure the Interaction between Microliter Aqueous Solutions and 1.0-17.0 GHz Radio Frequencies.

Mary Godfrey, Daniel Ewert, Ryan Striker, Benjamin Braaten

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 59% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mary GodfreyCollege of Engineering, North Dakota State University, Fargo, ND 58102, USA.
Daniel EwertCollege of Engineering and Mines, University of North Dakota, Grand Forks, ND 58202, USA.
Ryan StrikerCollege of Engineering and Mines, University of North Dakota, Grand Forks, ND 58202, USA.ORCID 0000-0001-9058-5636
Benjamin BraatenCollege of Engineering, North Dakota State University, Fargo, ND 58102, USA.ORCID 0000-0002-2575-7275
North Dakota State University · USUniversity of North Dakota · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Radio frequency (RF) biosensors are an expanding field of interest because of the ability to design noninvasive, label-free, low-production-cost sensing devices. Previous works identified the need for smaller experimental devices, requiring nanoliter to milliliter sampling volumes and increased capability of repeatable and sensitive measurement capability. The following work aims to verify a millimeter-sized, microstrip transmission line biosensor design with a microliter well operating on a broadband radio frequency range of 1.0-17.0 GHz. Three successive experiments were performed to provide evidence for (1) repeatability of measurements after loading/unloading the well, (2) sensitivity of measurement sets, and (3) methodology verification. Materials under test (MUTs) loaded into the well included deionized water, Tris-EDTA buffer, and lambda DNA. S-parameters were measured to determine interaction levels between the radio frequencies and MUTs during the broadband sweep. MUTs increasing in concentration were repeatably detected and demonstrated high measurement sensitivity, with the highest error value observed being 0.36%. Comparing Tris-EDTA buffer versus lambda DNA suspended in Tris-EDTA buffer suggests that introducing lambda DNA into the Tris-EDTA buffer repeatably alters S-parameters. The innovative aspect of this biosensor is that it can measure interactions of electromagnetic energy and MUTs in microliter quantities with high repeatability and sensitivity.

Indexed as

Biosensing TechniquesDNAEdetic AcidEquipment DesignWaterDNAEdetic AcidWaterbiosensingmicroliter sensormicrostrip transmission line sensorRF biosensor

Identifiers

PMID37299920
PMCPMC10255756
OpenAlexW4378882781

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked