ArticleSensors (Basel, Switzerland)2023
Smartphone Technology to Remotely Measure Postural Sway during Double- and Single-Leg Squats in Adults with Femoroacetabular Impingement and Those with No Hip Pain.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 8 citations in OpenAlex.
- Balance Assessments Using Smartphone Sensor Systems and a Clinician-Led Modified BESS Test in Soccer Athletes with Hip-Related Pain: An Exploratory Cross-Sectional Study.Sensors (Basel, Switzerland) · 2026Article
- Assessment of Pelvic Motion During Single-Leg Weight-Bearing Tasks Using Smartphone Sensors: Validity Study.JMIR rehabilitation and assistive technologies · 2025Article
- The Development and Validation of a Novel Smartphone Application to Detect Postural Instability.Sensors (Basel, Switzerland) · 2025Article
- Hip Active Range of Motion in Patients with Femoroacetabular Impingement Syndrome.Sensors (Basel, Switzerland) · 2025Article
- Smartphone Technology to Facilitate Remote Postural Balance Assessment in Acute Concussion Management: Pilot Study.Sensors (Basel, Switzerland) · 2024Article
- What the papers say.Journal of hip preservation surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe COVID-19 pandemic has accelerated the demand for utilising telehealth as a major mode of healthcare delivery, with increasing interest in the use of tele-platforms for remote patient assessment. In this context, the use of smartphone technology to measure squat performance in people with and without femoroacetabular impingement (FAI) syndrome has not been reported yet. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their squat performance in real time using the smartphone inertial sensors. The aim of this study was to investigate the association and test-retest reliability of the TelePhysio app in measuring postural sway performance during a double-leg (DLS) and single-leg (SLS) squat task. In addition, the study investigated the ability of TelePhysio to detect differences in DLS and SLS performance between people with FAI and without hip pain.
methodsA total of 30 healthy (nfemales = 12) young adults and 10 adults (nfemales = 2) with diagnosed FAI syndrome participated in the study. Healthy participants performed DLS and SLS on force plates in our laboratory, and remotely in their homes using the TelePhysio smartphone application. Sway measurements were compared using the centre of pressure (CoP) and smartphone inertial sensor data. A total of 10 participants with FAI (nfemales = 2) performed the squat assessments remotely. Four sway measurements in each axis (x, y, and z) were computed from the TelePhysio inertial sensors: (1) average acceleration magnitude from the mean (aam), (2) root-mean-square acceleration (rms), (3) range acceleration (r), and (4) approximate entropy (apen), with lower values indicating that the movement is more regular, repetitive, and predictable. Differences in TelePhysio squat sway data were compared between DLS and SLS, and between healthy and FAI adults, using analysis of variance with significance set at 0.05.
resultsThe TelePhysio aam measurements on the x- and y-axes had significant large correlations with the CoP measurements (r = 0.56 and r = 0.71, respectively). The TelePhysio aam measurements demonstrated moderate to substantial between-session reliability values of 0.73 (95% CI 0.62-0.81), 0.85 (95% CI 0.79-0.91), and 0.73 (95% CI 0.62-0.82) for aamx, aamy, and aamz, respectively. The DLS of the FAI participants showed significantly lower aam and apen values in the medio-lateral direction compared to the healthy DLS, healthy SLS, and FAI SLS groups (aam = 0.13, 0.19, 0.29, and 0.29, respectively; and apen = 0.33, 0.45, 0.52, and 0.48, respectively). In the anterior-posterior direction, healthy DLS showed significantly greater aam values compared to the healthy SLS, FAI DLS, and FAI SLS groups (1.26, 0.61, 0.68, and 0.35, respectively).
conclusionsThe TelePhysio app is a valid and reliable method of measuring postural control during DLS and SLS tasks. The application is capable of distinguishing performance levels between DLS and SLS tasks, and between healthy and FAI young adults. The DLS task is sufficient to distinguish the level of performance between healthy and FAI adults. This study validates the use of smartphone technology as a tele-assessment clinical tool for remote squat assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.