Evidence map›Paper›PMID 37299242›Full record

ArticlePolymers2023

Fabrication of CuO-NP-Doped PVDF Composites Based Electrospun Triboelectric Nanogenerators for Wearable and Biomedical Applications.

Bindhu Amrutha, Gajula Prasad, Ponnan Sathiyanathan, Mohammad Shamim Reza, Hongdoo Kim, Madhvesh Pathak, Arun Anand Prabu

Abstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Ferroelectric Material in Triboelectric Nanogenerator.Materials (Basel, Switzerland) · 2024
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bindhu AmruthaDepartment of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, India.
Gajula PrasadSchool of Energy, Materials and Chemical Engineering, Korea University of Technology and Education, 1600, Cheonan-si 31253, Chungcheongnam-do, Republic of Korea.ORCID 0000-0003-4274-9725
Ponnan SathiyanathanDepartment of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University, Yongin-si 17104, Gyeonggi-do, Republic of Korea.ORCID 0000-0001-9340-3340
Mohammad Shamim RezaDepartment of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University, Yongin-si 17104, Gyeonggi-do, Republic of Korea.
Hongdoo KimDepartment of Advanced Materials Engineering for Information & Electronics, College of Engineering, Kyung Hee University, Yongin-si 17104, Gyeonggi-do, Republic of Korea.
Madhvesh PathakDepartment of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, India.
Arun Anand PrabuDepartment of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, India.ORCID 0000-0001-5095-4820

Funding

MHRD-SPARC India No. 2018-2019/P399
6 · The paper itself

Abstract

A flexible and portable triboelectric nanogenerator (TENG) based on electrospun polyvinylidene fluoride (PVDF) doped with copper oxide (CuO) nanoparticles (NPs, 2, 4, 6, 8, and 10 wt.-% w.r.t. PVDF content) was fabricated. The structural and crystalline properties of the as-prepared PVDF-CuO composite membranes were characterized using SEM, FTIR, and XRD. To fabricate the TENG device, the PVDF-CuO was considered a tribo-negative film and the polyurethane (PU) a counter-positive film. The output voltage of the TENG was analyzed using a custom-made dynamic pressure setup, under a constant load of 1.0 kgf and 1.0 Hz frequency. The neat PVDF/PU showed only 1.7 V, which further increased up to 7.5 V when increasing the CuO contents from 2 to 8 wt.-%. A decrease in output voltage to 3.9 V was observed for 10 wt.-% CuO. Based on the above results, further measurements were carried out using the optimal sample (8 wt.-% CuO). Its output voltage performance was evaluated as a function of varying load (1 to 3 kgf) and frequency (0.1 to 1.0 Hz) conditions. Finally, the optimized device was demonstrated in real-time wearable sensor applications, such as human motion and health-monitoring applications (respiration and heart rate).

Indexed as

CuOelectrospinninghealth monitoringPVDFtriboelectric nanogenerator

Identifiers

PMID37299242
PMCPMC10255730

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.