Evidence map›Paper›PMID 37296699›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Evaluation of the Liquid Colony™ Produced by the FAST System for Shortening the Time of Bacterial Identification and Phenotypic Antimicrobial Susceptibility Testing and Detection of Resistance Mechanisms from Positive Blood Cultures.

Chiara Bonaiuto, Ilaria Baccani, Chiara Chilleri, Alberto Antonelli, Tommaso Giani, Gian Maria Rossolini

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Rapid diagnostic work-up ofAccess microbiology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chiara BonaiutoDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.
Ilaria BaccaniDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.
Chiara ChilleriDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.
Alberto AntonelliDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.ORCID 0000-0003-0295-6877
Tommaso GianiDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.
Gian Maria RossoliniDepartment of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundthe aim of this study was to evaluate the performance of the Liquid Colony™ (LC) generated directly from positive blood cultures (PBCs) by the FAST System (Qvella, Richmond Hill, ON, Canada) for rapid identification (ID) and antimicrobial susceptibility testing (AST) compared with the standard of care (SOC) workflow.

methodsAnonymized PBCs were processed in parallel by the FAST System and FAST PBC Prep cartridge (35 min runtime) and SOC. ID was performed by MALDI-ToF mass spectrometry (Bruker, Billerica, MA, USA). AST was performed by reference broth microdilution (Merlin Diagnostika, Bornheim, Germany). Carbapenemase detection was carried out with the lateral flow immunochromatographic assay (LFIA) RESIST-5 O.O.K.N.V. (Coris, Gembloux, Belgium). Polymicrobial PBCs and samples containing yeast were excluded.

results241 PBCs were evaluated. ID results showed 100% genus-level concordance and 97.8% species-level concordance between LC and SOC. The AST results for Gram-negative bacteria showed a categorical agreement (CA) of 99.1% (1578/1593), with minor error (mE), major error (ME), and very major error (VME) rates of 0.6% (10/1593), 0.3% (3/1122), and 0.4% (2/471), respectively. The results from Gram-positive bacteria showed a CA of 99.6% (1655/1662), with mE, ME, and VME rates of 0.3% (5/1662), 0.2% (2/1279), and 0.0% (0/378), respectively. Bias evaluation revealed acceptable results for both Gram-negatives and Gram-positives (-12.4% and -6.5%, respectively). The LC yielded the detection of 14/18 carbapenemase producers by LFIA. In terms of turnaround time, the ID, AST, and carbapenemase detection results were generally obtained one day earlier with the FAST System compared with the SOC workflow.

conclusionsThe ID, AST, and carbapenemase detection results generated with the FAST System LC were highly concordant with the conventional workflow. The LC allowed species ID and carbapenemase detection within around 1 h after blood culture positivity and AST results within approximately 24 h, which is a significant reduction in the turnaround time of the PBC workflow.

Indexed as

blood stream infectionfast microbiologyrapid ASTrapid CPE detectionrapid ID

Identifiers

PMID37296699
PMCPMC10253117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.