Evidence map›Paper›PMID 37296292›Full record

ArticleScientific reports2023

MATLAB simulation based study on poliovirus sensing through one-dimensional photonic crystal with defect.

Arafa H Aly, B A Mohamed, S K Awasthi, Suhad Ali Osman Abdallah, A F Amin

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Arafa H AlyTH-PPM Group, Physics Department, Faculty of Sciences, Beni-Suef University, Beni Suef, 62514, Egypt. arafa.hussien@science.bsu.edu.eg.ORCID http://orcid.org/0000-0003-0795-378X
B A MohamedTH-PPM Group, Physics Department, Faculty of Sciences, Beni-Suef University, Beni Suef, 62514, Egypt.
S K AwasthiDepartment of Physics and Material Science and Engineering, Jaypee Institute of Information Technology, Noida, 201304, India.ORCID http://orcid.org/0000-0003-3876-0075
Suhad Ali Osman AbdallahApplied College, Khamis Mushait, King Khalid University, Abha, 62529, Saudi Arabia.
A F AminFaculty of Technology and Education, Beni-Suef University, Beni Suef, 62521, Egypt.
Beni-Suef University · EGJaypee Institute of Information Technology · INKing Khalid University · SA

Funding

King Khalid University RGP. 2/220/43
6 · The paper itself

Abstract

The present work, theoretically examined the poliovirus sensor model composed of one-dimensional photonic crystal with defect. The transfer matrix method with the help of MATLAB software has been used to detect poliovirus present in the water sample. The main objective of the present work is to design an efficient sensor by identifying the minute variation in the refractive index of water sample due to change in the poliovirus concentration present in the sample. The alternate layers of aluminum nitride and gallium nitride has been taken to realize Bragg reflector having defect layer of air at center of the Bragg reflector. The effect of change in thickness of defect layer region, period number and incident angle corresponding to transverse electric wave has been examined to optimize the structure which correspond maximum performance of the proposed poliovirus sensing structure. The maximum performance of the structure has been obtained with optimum value of defect layer thickness 1200 nm, period number 10 and incident angle 40°. Under optimum condition maximum sensitivity of 1189.65517 nm/RIU has been obtained when the structure is loaded with waters sample of poliovirus concentration C = 0.005 g/ml whereas figure of merit, quality factor, signal to noise ratio, dynamic range, limit of detection and resolution values become 2618.28446 per RIU, 3102.06475, 2.27791, 2090.99500, 1.91E-05 and 0.24656 respectively.

Indexed as

PoliovirusComputer SimulationElectricitySoftwareWaterWater

Identifiers

PMID37296292
PMCPMC10256843
OpenAlexW4380090010

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.