Evidence map›Paper›PMID 37295282›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2023

Double cross magnetic wall decoupling for quadrature transceiver RF array coils using common-mode differential-mode resonators.

Komlan Payne, Aditya Ashok Bhosale, Xiaoliang Zhang

Open access · greenAbstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Multimodal surface coils for low field MR imaging.Magnetic resonance imaging · 2024
    Article
  4. Design of Multichannel Two-row Quadrature Transceive Array for Ultrahigh field MR Imaging.Proceedings of the International Society for Magnetic Resonance in Medicine ... Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition · 2024
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Komlan PayneDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA. Electronic address: komlanpa@buffalo.edu.
Aditya Ashok BhosaleDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA. Electronic address: adityaas@buffalo.edu.
Xiaoliang ZhangDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA; Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, NY 14260, USA. Electronic address: xzhang89@buffalo.edu.
Buffalo State University · US

Funding

Enhanced MR for morphological characterization of ligaments, tendons and boneU01EB023829 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LI, XIAOJUAN, ZHANG, XIAOLIANG · 2018 to 2024
$1.9M
NIBIB NIH HHS U01 EB023829
6 · The paper itself

Abstract

In contrast to linearly polarized RF coil arrays, quadrature transceiver coil arrays are capable of improving signal-to-noise ratio (SNR), spatial resolution, and parallel imaging performance. Owing to a reduced excitation power, a low specific absorption rate can also be obtained using quadrature RF coils. However, due to the complex nature of their structure and their electromagnetic properties, it is challenging to achieve sufficient electromagnetic decoupling while designing multichannel quadrature RF coil arrays, particularly in ultra-high fields. In this work, we proposed a double-cross magnetic wall decoupling for quadrature transceiver RF arrays and implemented the decoupling method on common-mode differential mode quadrature (CMDM) quadrature transceiver arrays at an ultrahigh field of 7 T. The proposed magnetic decoupling wall, comprised of two intrinsically decoupled loops, is used to reduce the mutual coupling between all the multi-mode currents present in the quadrature CMDM array. The decoupling network has no physical connection with the CMDMs' resonators, which provides less design constraint over size-adjustable RF arrays. To validate the feasibility of the proposed cross-magnetic decoupling wall, systematic studies on the decoupling performance based on the impedance of two intrinsic loops are numerically performed. A pair of quadrature transceiver CMDMs is constructed along with the proposed decoupling network, and their scattering matrix is characterized using a network analyzer. The measured results indicate that all the current modes from coupling are simultaneously suppressed using the proposed cross-magnetic wall. Moreover, field distribution and local specific absorption rate (SAR) are numerically obtained for a well-decoupled 8-channel quadrature knee-coil array.

Indexed as

High/low-impedance coilMagnetic resonance imagingMicrostrip transmission line resonatorParallel MRIRF coilUltra-high field

Identifiers

PMID37295282
PMCPMC10527004
OpenAlexW4379390370

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.