Evidence map›Paper›PMID 37293556›Full record

ArticleThe Journal of innovations in cardiac rhythm management2022

Incidence and Predictors of Implantable Cardioverter-defibrillator Therapies After Generator Replacement-A Pooled Analysis of 31,640 Patients' Data.

Dibbendhu Khanra, Subha Manivannan, Anindya Mukherjee, Saurabh Deshpande, Anunay Gupta, Wasim Rashid, Ahmed Abdalla, Peysh Patel, Deepak Padmanabhan, Indranill Basu-Ray

Open access · diamondAbstract read
In one paragraph

Article in The Journal of innovations in cardiac rhythm management, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 9 institutions in 3 countries.

Dibbendhu KhanraLiverpool Heart and Chest Hospital, Liverpool, UK.
Subha ManivannanAll India Institute of Medical Sciences, Rishikesh, India.
Anindya MukherjeeNRS Medical College, Kolkata, India.
Saurabh DeshpandeSri Jayadeva Institute of Cardiac Sciences and Research, Bengaluru, India.
Anunay GuptaVardhman Mahavir Medical College, and Safdarjung Hospital, New Delhi, India.
Wasim RashidGovernment Medical College, Shrinagar, India.
Ahmed AbdallaManchester University NHS Foundation Trust, Manchester, UK.
Peysh PatelQueen Elizabeth Hospital Birmingham, Birmingham, UK.
Deepak PadmanabhanSri Jayadeva Institute of Cardiac Sciences and Research, Bengaluru, India.
Indranill Basu-RayCardiovascular Research, Memphis Veteran Administration Hospital, Memphis, TN, USA.
Sri Jayadeva Institute of Cardiovascular Sciences and Research · INAll India Institute of Medical Sciences RishikeshGovernment Medical College · INManchester University NHS Foundation Trust · GBMedical College and Hospital, Kolkata · INMemphis VA Medical Center · USQueen Elizabeth Hospital Birmingham · GBUniversity of Liverpool · GBVardhman Mahavir Medical College & Safdarjung Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Among primary prevention implantable cardioverter-defibrillator (ICD) recipients, 75% do not experience any appropriate ICD therapies during their lifetime, and nearly 25% have improvements in their left ventricular ejection fraction (LVEF) during the lifespan of their first generator. The practice guidelines concerning this subgroup's clinical need for generator replacement (GR) remain unclear. We conducted a proportional meta-analysis to determine the incidence and predictors of ICD therapies after GR and compared this to the immediate and long-term complications. A systematic review of existing literature on ICD GR was performed. Selected studies were critically appraised using the Newcastle-Ottawa scale. Outcomes data were analyzed by random-effects modeling using R (R Foundation for Statistical Computing, Vienna, Austria), and covariate analyses were conducted using the restricted maximum likelihood function. A total of 31,640 patients across 20 studies were included in the meta-analysis with a median (range) follow-up of 2.9 (1.2-8.1) years. The incidences of total therapies, appropriate shocks, and anti-tachycardia pacing post-GR were approximately 8, 4, and 5 per 100 patient-years, respectively, corresponding to 22%, 12%, and 12% of patients of the total cohort, with a high level of heterogeneity across the studies. Greater anti-arrhythmic drug use and previous shocks were associated with ICD therapies post-GR. The all-cause mortality was approximately 6 per 100 patient-years, corresponding to 17% of the cohort. Diabetes mellitus, atrial fibrillation, ischemic cardiomyopathy, and the use of digoxin were predictors of all-cause mortality in the univariate analysis; however, none of these were found to be significant predictors in the multivariate analysis. The incidences of inappropriate shocks and other procedural complications were 2 and 2 per 100 patient-years, respectively, which corresponded to 6% and 4% of the entire cohort. Patients undergoing ICD GR continue to require therapy in a significant proportion of cases without any correlation with an improvement in LVEF. Further prospective studies are necessary to risk-stratify ICD patients undergoing GR.

Indexed as

Generator replacementimplantable cardioverter-defibrillatormortalitytherapy

Identifiers

PMID37293556
PMCPMC10246925
OpenAlexW4318967637

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.