Evidence map›Paper›PMID 37292286›Full record

ArticleHeliyon2023

Design modification of surgical drill bit for final osteotomy site preparation towards improved bone-implant contact.

Pravin Vasudeo Vaidya, Abir Dutta, Suparna Rooj, Rahul Talukdar, Komal Bhombe, Venkata Sundeep Seesala, Zahiruddin Quazi Syed, Tapas Kumar Bandyopadhyay, Santanu Dhara

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Pravin Vasudeo VaidyaAdvanced Technology Development Centre, IIT Kharagpur, West Bengal, India.
Abir DuttaAdvanced Technology Development Centre, IIT Kharagpur, West Bengal, India.
Suparna RoojAdvanced Technology Development Centre, IIT Kharagpur, West Bengal, India.
Rahul TalukdarAdvanced Technology Development Centre, IIT Kharagpur, West Bengal, India.
Komal BhombeSharad Pawar Dental Collage and Hospital, Dutta Meghe Institute of Medical Science, Wardha, Maharashtra, India.
Venkata Sundeep SeesalaSchool of Medical Science and Technology, IIT Kharagpur, West Bengal, India.
Zahiruddin Quazi SyedJawaharlal Nehru Medical College, Dutta Meghe Institute of Medical Science, Wardha, Maharashtra, India.
Tapas Kumar BandyopadhyayMetallurgical and Material Engineering, IIT Kharagpur, West Bengal, India.
Santanu DharaSchool of Medical Science and Technology, IIT Kharagpur, West Bengal, India.
Indian Institute of Technology Kharagpur · INDatta Meghe Institute of Higher Education and Research · INJawaharlal Nehru Medical College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Implant stability significantly impacts accelerated osseointegration, leading to faster patient recovery. Both primary and secondary stability necessitates superior bone-implant contact influenced by the surgical tool required to prepare the final osteotomy site. Besides, excessive shearing and frictional forces generate heat causing local tissue necrosis. Hence, surgical procedure necessitates proper irrigation with water to minimize heat generation. Notably, the water irrigation system removes bone chips and osseous coagulums, which may help accelerate osseointegration and improve bone-implant contact. The inferior bone-implant contact and thermal necrosis at the osteotomy site are primarily responsible for poor osseointegration and eventual failure. Therefore, optimizing tool geometry is key to minimizing shear force, heat generation, and necrosis during final osteotomy site preparation. The present study explores modified drilling tool geometry, especially cutting edge for osteotomy site preparation. The mathematical modeling is used to find out ideal cutting-edge geometry that facilitates drilling under relatively less operational force (0.55-5.24 N) and torque (98.8-154.5 N-mm) with a significant reduction (28.78%-30.87%) in heat generation. Twenty-three conceivable designs were obtained using the mathematical model; however, only three have shown promising results in static structural FEM platforms. These drill bits are designed for the final drilling operation and need to be carried out during the final osteotomy site preparation.

Indexed as

Bone implant contactDrill bitFrictional heatingNecrosisOsseointegration

Identifiers

PMID37292286
PMCPMC10245014
OpenAlexW4378374514

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked