Evidence map›Paper›PMID 37291484›Full record

ArticleBMC anesthesiology2023

Rebounds of sevoflurane concentration during simulated trigger-free pediatric and adult anesthesia.

Simon Zumsande, Christian Thoben, Nils Dennhardt, Terence Krauß, Robert Sümpelmann, Stefan Zimmermann, Henrik Rüffert, Sebastian Heiderich

Open access · goldAbstract read
In one paragraph

Article in BMC anesthesiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Simon ZumsandeClinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Christian ThobenInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover, Germany.ORCID 0000-0002-5415-2320
Nils DennhardtClinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.ORCID 0000-0003-3831-1608
Terence KraußClinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Robert SümpelmannClinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.ORCID 0000-0001-5850-7443
Stefan ZimmermannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, Hannover, Germany.ORCID 0000-0002-1725-6657
Henrik RüffertClinic of Anesthesiology and Intensive Care Medicine, Helios Klinik Schkeuditz, Leipzig, Germany.
Sebastian HeiderichClinic of Anesthesiology and Intensive Care Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. heiderich.sebastian@mh-hannover.de.ORCID 0000-0002-5742-5558
Medizinische Hochschule Hannover · DELeibniz University Hannover · DEHelios Kliniken · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn trigger-free anesthesia a volatile anesthetic concentration of 5 parts per million (ppm) should not be exceeded. According to European Malignant Hyperthermia Group (EMHG) guideline, this may be achieved by removing the vapor, changing the anesthetic breathing circuit and renewing the soda lime canister followed by flushing with O

methodsA Dräger® Primus® was contaminated with decreasing concentrations of sevoflurane for 120 min. Then, the machine was prepared for trigger-free anesthesia according to EMHG guideline by changing recommended parts and flushing the breathing circuits using 10 or 18 l⋅min

resultsImmediately after start of simulated anesthesia, there was an initial peak of 11-18 ppm sevoflurane in all experiments. The concentration dropped below 5 ppm after 2-3 min during adult and 4-18 min during pediatric ventilation. Other rebounds of sevoflurane > 5 ppm occurred after apnea, DLC and PSV. MV resulted in a decrease of sevoflurane < 5 ppm within 1 min.

conclusionThis study shows that after guideline-compliant preparation for trigger-free ventilation anesthetic machines may develop rebounds of sevoflurane > 5 ppm during typical maneuvers used in clinical practice. The changes in rate and direction of internal gas flow during different ventilation modes and maneuvers are possible explanations. Therefore, manufacturers should provide machine-specific washout protocols or emphasize the use of active charcoal filters (ACF) for trigger-free anesthesia.

Indexed as

AnesthesiaAnesthetics, InhalationMalignant HyperthermiaMethyl EthersAdultApneaChildGasesHumansSevofluraneAnesthetics, InhalationGasesMethyl EthersSevofluraneActive charcoal filtersMalignant hyperthermiaPatient safetyPediatric anesthesiaRebound effectTrigger-free anesthesiaVolatile anestheticsWashout method

Identifiers

PMID37291484
PMCPMC10249316
OpenAlexW4379967198

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.