ArticleClinical research in cardiology : official journal of the German Cardiac Society2024
Impact of left atrial appendage occlusion device position on potential determinants of device-related thrombus: a patient-specific in silico study.
Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 11 citations in OpenAlex.
- An integrated fluid-dynamic and structural pipeline to assess atrial hemodynamics before and after left atrial appendage occluder deployment in a patient-specific anatomy.Medical & biological engineering & computing · 2026Article
- Anatomical and Imaging Predictors of Peri-Device Leak Following Left Atrial Appendage Closure Using the LAmbre Device: A Comparative Study of CCTA and TEE.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Article
- Virtual left atrial appendage occlusion in paroxysmal atrial fibrillation during sinus rhythm predicts variable reductions in blood stasis.The Journal of physiology · 2026Article
- Imaging-defined residual risk after left atrial appendage occlusion: from device surveillance to antithrombotic and reintervention decision considerations.Frontiers in cardiovascular medicine · 2026Review
- Double Trouble: A Bifid Left Atrial Appendage Requiring a Double Lobe-and-Disk Device Approach.CASE (Philadelphia, Pa.) · 2025Article
- Flow Dynamic Factors Correlated With Device-Related Thrombosis After Left Atrial Appendage Occlusion.JACC. Advances · 2024Article
- Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus.PLoS computational biology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDevice-related thrombus (DRT) after left atrial appendage occlusion (LAAO) is potentially linked to adverse events. Although clinical reports suggest an effect of the device type and position on the DRT risk, in-depth studies of its mechanistic basis are needed. This in silico study aimed to assess the impact of the position of non-pacifier (Watchman) and pacifier (Amulet) LAAO devices on surrogate markers of DRT risk.
methodsThe LAAO devices were modeled with precise geometry and virtually implanted in different positions into a patient-specific left atrium. Using computational fluid dynamics, the following values were quantified: residual blood, wall shear stress (WSS) and endothelial cell activation potential (ECAP).
resultsIn comparison to an ostium-fitted device position, deep implantation led to more residual blood, lower average WSS and higher ECAP surrounding the device, especially on the device's atrial surface and the surrounding tissue, suggesting increased risk for potential thrombus. For the non-pacifier device, an off-axis device orientation resulted in even more residual blood, higher ECAP and similar average WSS as compared to an ostium-fitted device position. Overall, the pacifier device showed less residual blood, higher average WSS and lower ECAP, compared to the non-pacifier device.
conclusionsIn this in silico study, both LAAO device type and implant position showed an impact on potential markers of DRT in terms of blood stasis, platelet adhesion and endothelial dysfunction. Our results present a mechanistic basis for clinically observed risk factors of DRT and the proposed in silico model may aid in the optimization of device development and procedural aspects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.