ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2024
Mid-term outcomes and hemodynamic performance of the St Jude Medical Epic aortic bioprosthesis for severe aortic stenosis.
Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The St. Jude Medical Epic Supra valve is a porcine bioprosthesis designed for complete supraannular implantation. No report has shown the hemodynamic performance and clinical outcomes of aortic valve replacement with the Epic Supra valve for severe aortic stenosis in a Japanese cohort. We retrospectively evaluated 65 patients who underwent aortic valve replacement using the Epic Supra valve for aortic stenosis at our department between May, 2011 and October, 2016. The mean follow-up period was 68.7 ± 32.7 months, and the follow-up rate was 89.2%. The mean age was 76.8 ± 5.3 years. The 1-, 5-, and 8-year survival rates were 96.9%, 79.4%, and 60.3%, respectively. The rates of freedom from valve-related events were 96.6% and 81.9% at 5 and 8 years, respectively. Four patients were diagnosed with structural valve deterioration (SVD), and reintervention was performed in two patients. The rates of freedom from SVD were 98.2% and 83.3% at 5 and 8 years, respectively, and the mean time to diagnosis of SVD was 72.5 ± 25.3 months. The mean pressure gradient (MPG) was 16.8 ± 6.0 mmHg postoperatively, 17.5 ± 9.4 mmHg at 5 years, and 21.2 ± 12.4 mmHg at 8 years (p = 0.08). The effective orifice area index (EOAI) was 0.95 ± 0.2 cm2/m2 immediately after surgery, 0.96 ± 0.27 cm2/m2 at 5 years, and 0.84 ± 0.2 cm2/m2 at 8 years (p = 0.10). An increase in MPG and decrease in EOAI were also observed, which may be associated with SVD. Follow-up after 5 years is important to determine if there is an increase.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.