Evidence map›Paper›PMID 37288118›Full record

ArticleStructural heart : the journal of the Heart Team2022

Synchronized Diaphragmatic Stimulation for Heart Failure With a Reduced Left Ventricular Ejection Fraction Using the VisONE System: A First-in-Patient Study With Extended Population.

Ana Jorbenadze, Lee R Goldberg, Tamaz Shaburishvili, Michel Zuber, Michael Mirro, Marat Fudim

Open access · goldAbstract read
In one paragraph

Article in Structural heart : the journal of the Heart Team, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 2 countries.

Ana JorbenadzeHeart and Vascular Clinic, Tbilisi, Georgia.
Lee R GoldbergDivision of Cardiovascular Medicine, Section of Advanced Heart Failure and Cardiac Transplant, University of Pennsylvania, Pennsylvania, USA.
Tamaz ShaburishviliHeart and Vascular Clinic, Tbilisi, Georgia.
Michel ZuberHeart Center, Kantonsspital Aarau, Aarau, Switzerland.
Michael MirroSchool of Medicine, Indiana University, Fort Wayne, Indiana, USA.
Marat FudimDepartment of Medicine, Duke University Medical Center, Durham, North Carolina, USA.
United Heart and Vascular Clinic · USClinical Research Institute · USIndiana University Fort Wayne · USKantonsspital Aarau · CHUniversity of Pennsylvania · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Synchronized diaphragmatic stimulation (SDS) produces localized contractions of the diaphragm gated to the cardiac cycle to transiently modulate intrathoracic pressures, thereby impacting cardiac function for heart failure patients with reduced ejection fraction (HFrEF). This study prospectively evaluated the safety and 1-year effectiveness of SDS in an expanded first-in-patient cohort using multiple implant methods. Methods: Symptomatic patients with HFrEF despite guideline-directed therapy were enrolled. Patients were evaluated at 3, 6 and 12 months for adverse events, quality of life (SF-36 QOL), echocardiography and 6-minute hall walk distance. The SDS system consists of 2 bipolar, active-fixation leads, and an implantable pulse generator. Results: Nineteen men were enrolled (age 63 [57, 67] years, New York Heart Association class II [53%]/III [47%], N-terminal pro B-type natriuretic peptide 1779 [886, 2309] pg/mL, left ventricular ejection fraction 27 [23, 33] %). Three implant techniques (abdominal laparoscopy: sensing and stimulating leads on the inferior diaphragm (n = 15); subxiphoid access for an epicardial sensing lead and abdominal laparoscopy for stimulation on the inferior diaphragm (n = 2); thoracoscopy to place an epicardial sensing lead and a stimulating lead on the superior diaphragm (n = 2)) were employed with 100% success. Patients were unaware of diaphragmatic stimulation. From discharge to 12 months, 6-minute hall walk distance increased (315 [296, 332]m to 340 [319, 384]m; Conclusions: These data demonstrate that SDS can be delivered using alternative implantation methods without raising safety concerns and suggest improved outcomes over 1 ​year of follow-up. Adequately powered randomized trials are now needed to confirm these findings.

Indexed as

Acute cardiac hemodynamicsHeart failureSynchronized diaphragmatic stimulation

Identifiers

PMID37288118
PMCPMC10242567
OpenAlexW4307897071

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.