ArticleMedical & biological engineering & computing2023
Volatile organic compound sensing in breath using conducting polymer coated chemi-resistive filter paper sensors.
Article in Medical & biological engineering & computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Comprehensive Review on Sustainable Triboelectric Energy Harvesting Using Biowaste-Derived Materials.Materials (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this work, a disposable sensor array was designed based on the chemi-resistive behavior of the conducting polymers to detect three volatile organic compounds (VOCs), i.e., acetone, ethanol, and methanol in air and breath. Four disposable resistive sensors were designed by coating polypyrrole and polyaniline (in their doped and de-doped forms) on filter paper substrates and tested against VOCs in air. Change in conductivity of the polymer resulting from exposure to various VOC concentration was measured as percentage resistance change using a standard multimeter. The lowest concentration detected for acetone, ethanol, and methanol vapors was 400 ppb, 150 ppb, and 300 ppb, respectively within 2 min. These VOC-responsive sensors, housed in an indigenous inert chamber, showed good stability, repeatability, and reversibility while sensing, thus making it suitable for environmental pollutant detection at room temperature. Furthermore, the non-specific nature of these easy to fabricate sensors towards all VOCs is considered favorable and upon classifying with principal component analysis (PCA), the gases were qualitatively distinguished in separate clusters. These developed sensors were also tested and analyzed using VOC spiked real breath samples as proof of concept.
Indexed as
Identifiers
37286862What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.