Evidence map›Paper›PMID 37286750›Full record

ArticleSurgical endoscopy2023

Quantification of indocyanine green near-infrared fluorescence bowel perfusion assessment in colorectal surgery.

Robin A Faber, Floris P Tange, Hidde A Galema, Thomas C Zwaan, Fabian A Holman, Koen C M J Peeters, Pieter J Tanis, Cornelis Verhoef, Jacobus Burggraaf, J Sven D Mieog and 5 more

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07098182 (Clinical Study Evaluating the Contribution of Preserving the Superior Left Colic Artery to the Vascularization of the Descending Colon Prior to Colorectal Anastomosis During Left-Sided or Rectal Resections for Colorectal or Ovarian Cancer.), which is not on this map. Cited by 25 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed, 2 pooled it
7.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07098182 narecruitingnot on this mapstarted 2025, after this paper: background citation

Clinical Study Evaluating the Contribution of Preserving the Superior Left Colic Artery to the Vascularization of the Descending Colon Prior to Colorectal Anastomosis During Left-Sided or Rectal Resections for Colorectal or Ovarian Cancer. (Revascularisation Colique)

TypeinterventionalSponsorInstitut du Cancer de Montpellier - Val d'AurelleRan2025 to 2026Enrolled50ConditionsRectal Cancer, Colon Cancer, Ovarian CancerArmsClamping and restauration of arterial blood of the inferior mesenteric artery
3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 2 syntheses or guidelines pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Surgical Interventions for NEC-An Overview.Children (Basel, Switzerland) · 2026
    Review
  5. Robust quantification of ICG fluorescence perfusion in neonatal bowel surgery via deep point tracking.International journal of computer assisted radiology and surgery · 2026
    Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Observational
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 3 institutions in 2 countries.

Robin A Faber *Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.ORCID 0000-0002-4338-2745
Floris P Tange *Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Hidde A Galema *Department of Surgical Oncology and Gastrointestinal Surgery, Erasmus MC Cancer Institute, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Thomas C ZwaanDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Fabian A HolmanDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Koen C M J PeetersDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Pieter J TanisDepartment of Surgical Oncology and Gastrointestinal Surgery, Erasmus MC Cancer Institute, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Cornelis VerhoefDepartment of Surgical Oncology and Gastrointestinal Surgery, Erasmus MC Cancer Institute, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Jacobus BurggraafDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
J Sven D MieogDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Merlijn HuttemanDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Stijn KeereweerDepartment of Otorhinolaryngology and Head and Neck Surgery, Erasmus MC Cancer Institute, Doctor Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.
Alexander L VahrmeijerDepartment of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Joost R van der Vorst *Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
Denise E Hilling *Department of Surgery, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands. d.e.hilling@lumc.nl.
Leiden University Medical Center · NLErasmus MC Cancer Institute · NLRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIndocyanine green near-infrared fluorescence bowel perfusion assessment has shown its potential benefit in preventing anastomotic leakage. However, the surgeon's subjective visual interpretation of the fluorescence signal limits the validity and reproducibility of the technique. Therefore, this study aimed to identify objective quantified bowel perfusion patterns in patients undergoing colorectal surgery using a standardized imaging protocol.

methodA standardized fluorescence video was recorded. Postoperatively, the fluorescence videos were quantified by drawing contiguous region of interests (ROIs) on the bowel. For each ROI, a time-intensity curve was plotted from which perfusion parameters (n = 10) were derived and analyzed. Furthermore, the inter-observer agreement of the surgeon's subjective interpretation of the fluorescence signal was assessed.

resultsTwenty patients who underwent colorectal surgery were included in the study. Based on the quantified time-intensity curves, three different perfusion patterns were identified. Similar for both the ileum and colon, perfusion pattern 1 had a steep inflow that reached its peak fluorescence intensity rapidly, followed by a steep outflow. Perfusion pattern 2 had a relatively flat outflow slope immediately followed by its plateau phase. Perfusion pattern 3 only reached its peak fluorescence intensity after 3 min with a slow inflow gradient preceding it. The inter-observer agreement was poor-moderate (Intraclass Correlation Coefficient (ICC): 0.378, 95% CI 0.210-0.579).

conclusionThis study showed that quantification of bowel perfusion is a feasible method to differentiate between different perfusion patterns. In addition, the poor-moderate inter-observer agreement of the subjective interpretation of the fluorescence signal between surgeons emphasizes the need for objective quantification.

Indexed as

Colorectal NeoplasmsColorectal SurgeryAnastomosis, SurgicalAnastomotic LeakHumansIndocyanine GreenPerfusionReproducibility of ResultsIndocyanine GreenBowel perfusionColorectal surgeryFluorescence imagingIndocyanine greenQuantification

Identifiers

PMID37286750
PMCPMC10462565
OpenAlexW4379768791

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.