Evidence map›Paper›PMID 37286735›Full record

ArticleScientific reports2023

Simultaneous determination of 2-(3-hydroxy-5-phosphonooxymethyl-2-methyl-4-pyridyl)-1,3-thiazolidine-4-carboxylic acid and main plasma aminothiols by HPLC-UV based method.

Justyna Piechocka, Monika Wyszczelska-Rokiel, Rafał Głowacki

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Justyna PiechockaDepartment of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska Str., 90-236, Łódź, Poland. justyna.piechocka@chemia.uni.lodz.pl.
Monika Wyszczelska-RokielDepartment of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska Str., 90-236, Łódź, Poland.
Rafał GłowackiDepartment of Environmental Chemistry, Faculty of Chemistry, University of Lodz, 163/165 Pomorska Str., 90-236, Łódź, Poland. rafal.glowacki@chemia.uni.lodz.pl.
University of Łódź · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The report presents the first method for simultaneous determination of plasma 2-(3-hydroxy-5-phosphonooxymethyl-2-methyl-4-pyridyl)-1,3-thiazolidine-4-carboxylic acid (HPPTCA), an adduct of cysteine (Cys) and active form of vitamin B6 pyridoxal 5'-phosphate (PLP), as well as total low molecular-weight thiols content, including Cys, homocysteine (Hcy), cysteinyl-glycine (Cys-Gly), and glutathione (GSH). The assay is based on high performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) and involves disulfides reduction with tris(2-carboxyethyl)phosphine (TCEP), derivatization with 2-chloro-1-methylquinolinium tetrafluoroborate (CMQT) followed by sample deproteinization with perchloric acid (PCA). The chromatographic separation of obtained stable UV-absorbing derivatives is achieved on ZORBAX SB-C18 (150 × 4.6 mm, 5.0 µm) column using gradient elution with eluent consisted of 0.1 mol/L trichloroacetic acid (TCA), pH 1.7 and acetonitrile (ACN), delivered at a flow rate 1 mL/min. Under these conditions, the analytes are separated within 14 min at room temperature, and quantified by monitoring at 355 nm. Regarding HPPTCA, the assay linearity was demonstrated within a 1-100 µmol/L in plasma and the lowest concentration on the calibration curve was recognized as the limit of quantification (LOQ). The accuracy ranged from 92.74 to 105.57% and 95.43 to 115.73%, while precision varied from 2.48 to 6.99% and 0.84 to 6.98% for intra- and inter-day measurements, respectively. The utility of the assay was proved by application to plasma samples delivered by apparently healthy donors (n = 18) in which the HPPTCA concentration ranged from 19.2 to 65.6 µmol/L. The HPLC-UV assay provides complementary tool for routine clinical analysis, facilitating further studies on the role of aminothiols and HPPTCA in living systems.

Indexed as

CysteineSulfhydryl CompoundsChromatography, High Pressure LiquidGlutathionePyridoxal PhosphateReproducibility of ResultsThiazolidinesCysteineGlutathionePyridoxal PhosphateSulfhydryl Compoundsthiazolidine-4-carboxylic acidThiazolidines

Identifiers

PMID37286735
PMCPMC10247705
OpenAlexW4379743545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.