ArticleThe Indian journal of medical research2023
Effect of the timing of insertion of postpartum intrauterine contraceptive device (PPIUCD) copper T380A on expulsion rates.
Article in The Indian journal of medical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background & objectives: Postpartum intrauterine contraceptive device (PPIUCD) is well accepted and recommended for contraception. However, anxiety at the time of delivery may restrict the acceptance of a PPIUCD for its immediate insertion. So far there is limited evidence to conclude anything concrete on the association between the expulsion rates and the timing of insertion following a vaginal delivery. Thus, this study was undertaken to compare the expulsion rates in immediate and early insertions and their safety and complications. Methods: This prospective comparative study was carried out over 17 months on women delivering vaginally in a tertiary care teaching hospital in South India. A copper device (CuT380A) was inserted using Kelly's placental forceps either within 10 min of placental delivery (immediate group, n=160) or between 10 min upto 48 h postpartum (early group, n=160). Ultrasound was done before discharge from the hospital. The expulsion rates and any other complications at six-week and three-month follow up were studied. Chi-square test was used to compare the difference in expulsion rates. Results: The expulsion rate was five per cent in the immediate compared to 3.7 per cent in the early group (no significant difference). In ten cases, the device was found to be in the lower uterus upon ultrasound before discharge. These were repositioned. There was no case with perforation, irregular bleeding or infection up to the three-month follow up. Higher age, higher parity, lack of satisfaction and motivation to continue were predictors of expulsion. Interpretation & conclusions: In the present study PPIUCD was found to be safe with overall expulsion in 4.3 per cent. It was marginally, though not significantly, higher in the immediate group.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.