Evidence map›Paper›PMID 37280759›Full record

ArticleInternational neurourology journal2023

A Novel Incisionless Disposable Vaginal Device for Female Stress Urinary Incontinence: Efficacy and Quality of Life.

Chung Lyul Lee, Jong Mok Park, Ji Yong Lee, Seung Woo Yang, Hyun Seok Na, Jaegeun Lee, Sunkyung Jung, Ju Hyun Shin

Open access · diamondAbstract read
In one paragraph

Article in International neurourology journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Dynamics in Neurourology.International neurourology journal · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Chung Lyul LeeDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Jong Mok ParkDepartment of Urology, Chungnam National University Sejong Hospital, Sejong, Korea.
Ji Yong LeeDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Seung Woo YangDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Hyun Seok NaDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Jaegeun LeeDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Sunkyung JungDepartment of Urology, Chungnam National University Sejong Hospital, Sejong, Korea.
Ju Hyun ShinDepartment of Urology, Chungnam National University Hospital, Daejeon, Korea.
Chungnam National University Hospital · KRChungnam National University · KR

Funding

RimHealthcare, Inc.
6 · The paper itself

Abstract

purposeThis clinical study sought to evaluate the possible clinical effectiveness and practicality of URINO, an innovative, incisionless, and disposable intravaginal device, designed for patients suffering from stress urinary incontinence.

methodsA prospective, multicenter, single-arm clinical trial was carried out, involving women diagnosed with stress urinary incontinence who used a self-inserted, disposable intravaginal pessary device. Comparisons were made between the results of the 20-minute pad-weight gain (PWG) test at baseline and visit 3, where the device was applied. After 1 week of device usage, compliance, satisfaction, the sensation of a foreign body, and adverse events were assessed.

resultsOut of 45 participants, 39 completed the trial and expressed satisfaction within the modified intention-to-treat group. The average 20-minute PWG of participants was 17.2±33.6 g at baseline and significantly dropped to 5.3±16.2 g at visit 3 with device application. A total of 87.2% of participants exhibited a reduction ratio of PWG by 50% or more, surpassing the clinical trial success benchmark of 76%. The mean compliance was recorded as 76.6%±26.6%, the average visual analogue scale score for patient satisfaction was 6.4±2.6, and the sensation of a foreign body, measured on a 5-point Likert scale, was 3.1±1.2 after 1 week of device use. No serious adverse events were reported; there was 1 instance of microscopic hematuria and 2 cases of pyuria, all of which recovered.

conclusionThe investigated device demonstrated significant clinical effectiveness and safety for patients with stress urinary incontinence. It was easy to use, showing favorable patient compliance. We propose that these disposable intravaginal pessaries could potentially be an alternative treatment for patients with stress urinary incontinence who are seeking nonsurgical options or are unable to undergo surgery. Trial Registration: The study was registered as a clinical trial (KCT0008369).

Indexed as

MidurethraPessariesUrinary incontinence, Stress

Identifiers

PMID37280759
PMCPMC10263161
OpenAlexW4378647213

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.