Evidence map›Paper›PMID 37280757›Full record

ArticleInternational neurourology journal2023

Advancing Patient Care: Innovative Use of Near-Infrared Spectroscopy for Monitoring Urine Volume in Neurogenic Bladder.

Byeong-Il Kang, Aram Kim, Sehwan Kim

Open access · diamondAbstract read
In one paragraph

Article in International neurourology journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Dynamics in Neurourology.International neurourology journal · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Byeong-Il KangDepartment of Biomedical Engineering, Beckman Laser Institute Korea, School of Medicine, Dankook University, Cheonan, Korea.
Aram KimDepartment of Biomedical Engineering, Beckman Laser Institute Korea, School of Medicine, Dankook University, Cheonan, Korea.
Sehwan KimDepartment of Biomedical Engineering, Beckman Laser Institute Korea, School of Medicine, Dankook University, Cheonan, Korea.
Korea Pharma (South Korea) · KRKonkuk University Medical Center · KR

Funding

Korea Technology Information Promotion AgencyMinistry of EducationMinistry of Science and TechnologyMinistry of SMEs and Startups S3321192National Research Foundation of Korea 2022R1I1A3073688National Research Foundation of Korea 2023K1A4A3A02057280
6 · The paper itself

Abstract

purposeCurrent guidelines recommend clean intermittent catheterization (CIC) at regular time intervals for patients with spinal cord injuries; however, many patients experience difficulties. Performing time-based CIC outside the home is a significant burden for patients. In this study, we aimed to overcome the limitations of the current guidelines by developing a digital device to monitor bladder urine volume in real-time.

methodsThe optode sensor is a near-infrared spectroscopy (NIRS)-based wearable device intended to be attached to the skin of the lower abdomen where the bladder is located. The sensor's primary function is to detect changes in urine volume within the bladder. An in vitro study was conducted using a bladder phantom that mimicked the optical properties of the lower abdomen. To validate the data in the human body at the proof-of-concept level, one volunteer attached the device to the lower abdomen to measure the light intensity between the first voiding and immediately before the second voiding.

resultsThe degree of attenuation at the maximum test volume was equivalent across experiments, and the optode sensor with multiplex measurements demonstrated robust performance for patient diversity. Moreover, the symmetric feature of the matrix was deemed a potential parameter for identifying the accuracy of sensor localization in a deep-learning model. The validated feasibility of the sensor showed almost the same results as an ultrasound scanner, which is routinely used in the clinical field.

conclusionThe optode sensor of the NIRS-based wearable device can measure the urine volume in the bladder in real-time.

Indexed as

Bladder monitoringClean intermittent catheterizationNeurogenic bladder

Identifiers

PMID37280757
PMCPMC10263163
OpenAlexW4378647182

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.