Evidence map›Paper›PMID 37280604›Full record

ArticleBMC oral health2023

The relative area score for sublingual varices reliability measurement: a diagnostic study.

Christian R Klein, David Stoppenbrink, Jannik Geier, Andreas Mayr, Helmut Stark

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Christian R KleinDepartment of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, Rheinische Friedrich-Wilhelms University, University of Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany. christian.klein@ukbonn.de.
David StoppenbrinkDepartment of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, Rheinische Friedrich-Wilhelms University, University of Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany.
Jannik GeierDepartment of Oral, Maxillofacial and Plastic Surgery, Center of Dento-Maxillo-Facial Medicine, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany.
Andreas MayrDepartment of Medical Biometry, Informatics and Epidemiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Helmut StarkDepartment of Prosthetic Dentistry, Preclinical Education and Materials Science, Dental School, Rheinische Friedrich-Wilhelms University, University of Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany.
University of Bonn · DEUniversity Hospital Bonn · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitus and age. Despite many prevalence studies, it is still unclear how the reliability of SV inspection affects its predictive power. The aim of this study was to quantify the inspection reliability of SV.

methodsIn a diagnostic study, the clinical inspection of 78 patients by 23 clinicians was examined for the diagnosis of SV. Digital images of the underside of the tongue were taken from each patient. The physicians were then asked to rate them for the presence of sublingual varices (0/1) in an online inspection experiment. Statistical analysis for inter-item and inter-rater reliability was performed in a τ-equivalent measurement model with Cronbach's [Formula: see text] and Fleiss κ.

resultsThe interrater reliability for sublingual varices was relatively low with κ = 0.397. The internal consistency of image findings for SV was relatively high with α≈ 0.937. This shows that although SV inspection is possible in principle, it has a low reliability R. This means that the inspection finding (0/1) of individual images often cannot be reproduced stably. Therefore, SV inspection is a difficult task of clinical investigation. The reliability R of SV inspection also limits the maximum linear correlation [Formula: see text] of SV with an arbitrary other parameter Y. The reliability of SV inspection R = 0.847 limits the maximum correlation to [Formula: see text] (SV, Y) = 0,920-a 100% correlation was a priori not achievable in our sample. To overcome the problem of low reliability in SV inspection, we propose the RA (relative area) score as a continuous classification system for SV, which normalises the area of visible sublingual veins to the square of the length of the tongue, providing a dimensionless measure of SV.

conclusionsThe reliability of the SV inspection is relatively low. This limits the maximum possible correlation of SV with other (clinical) parameters. SV inspection reliability is an important indicator for the quality of SV as a predictive marker. This should be taken into account when interpreting previous studies on SV and has implications for future studies. The RA score could help to objectify the SV examination and thus increase its reliability.

Indexed as

Diabetes Mellitus, Type 2HypertensionVaricose VeinsHumansReproducibility of ResultsTongueAgingClinical inspectionClinical markersMaximum correlationOral sciencePreventive health careReliabilitySublingual varices

Identifiers

PMID37280604
PMCPMC10242773
OpenAlexW4379538258

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.