ArticleDiabetes therapy : research, treatment and education of diabetes and related disorders2023
Real-World User and Clinician Perspective and Experience with MiniMed™ 780G Advanced Hybrid Closed Loop System.
Article in Diabetes therapy : research, treatment and education of diabetes and related disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 13 citations in OpenAlex.
- Diabetes Educators' Perspectives on MiniMed™ 780G Onboarding: Insights from a Multiregional Survey Across Europe, the Middle East, and Africa.Advances in therapy · 2026Article
- Nanostructured electrode materials and flexible-substrate engineering for wearable multi-analyte biosensors in diabetes monitoring and personalized care: a comprehensive review.Journal of materials science. Materials in medicine · 2026Review
- Efficacy of an advanced hybrid closed-loop system in a patient with type 1 diabetes and intellectual disability: a case report.Frontiers in endocrinology · 2025Article
- Observational
- Closed-loop systems: recent advancements and lived experiences.Expert review of medical devices · 2024Review
- Improving glycemic control by transitioning from the MiniMedEndocrine journal · 2024Observational
- A sensor-augmented pump with a predictive low-glucose suspend system could lead to an optimal time in target range during pregnancy in Japanese women with type 1 diabetes.Diabetology international · 2024Article
- A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting.Diabetes care · 2024Article
- User experiences during the transition to calibration-free sensors with remote monitoring while using automated insulin delivery - a qualitative study.Frontiers in endocrinology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe advanced hybrid closed loop (AHCL) MiniMed™ 780G system changes basal insulin delivery every 5 min and auto bolus in response to sensor glucose values. We assessed the performance of the AHCL system in real-world settings for individuals with type 1 diabetes (T1DM) as well as user and clinician perspectives and satisfaction.
methodsWe held two peer group discussions: one having adults with T1DM/parents of children and adolescents with T1DM to understand their experiences with the AHCL system and another with healthcare providers (HCPs). Responses from the discussions were analyzed and categorized into themes by two independent researchers, with any inconsistencies resolved by consensus. We also analyzed data from the system uploaded to CareLink personal software. Glycemic outcomes, including time in range (TIR), time below range (TBR), time above range (TAR), mean sensor glucose (SG) levels, glucose management indicator (GMI), sensor use, and percentage of time spent in AHCL, were determined.
resultsThe peer group discussions revealed numerous key themes and issues for each group, such as the significance of setting reasonable expectations, carbohydrate counting and bolus dosing, technical difficulties, and overall user experience. The users (n = 25; T1DM; 17 female; age 13.8 ± 7.49 years; A1C 6.54 ± 0.45%; duration of diabetes 6 ± 6.78 years) were very satisfied with the system. Most users experienced consistent blood glucose values with very few hypoglycemic episodes. However, there were a few limitations reported, such as hyperglycemic episodes caused by inaccuracies in carb counting, issues with sensor connectivity, and cannula blockages or kinking for those using insulin Fiasp. Users achieved a mean GMI of 6.4 ± 0.26%, TIR of 83.0 ± 8.12%, TBR (54-70 mg/dL) of 2.0 ± 0.81%, TBR* (< 54 mg/dL) of 0%. All of the users achieved a TIR of > 70%.
conclusionThe use of the AHCL system in T1DM resulted in robust glycemic control, minimizing hypoglycemia. Providing training to both users and HCPs can help them use the system effectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.