Evidence map›Paper›PMID 37277712›Full record

ArticleBMC bioinformatics2023

RegiSTORM: channel registration for multi-color stochastic optical reconstruction microscopy.

Øystein Øvrebø, Miina Ojansivu, Kimmo Kartasalo, Hanna M G Barriga, Petter Ranefall, Margaret N Holme, Molly M Stevens

Open access · goldAbstract read
In one paragraph

Article in BMC bioinformatics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Øystein Øvrebø *Department of Materials, Imperial College London, London, SW7 2AZ, UK.
Miina Ojansivu *Department of Medical Biochemistry and Biophysics, Karolinska Institute, 171 77, Stockholm, Sweden.
Kimmo KartasaloDepartment of Medical Epidemiology and Biostatistics, Karolinska Institute, 171 77, Stockholm, Sweden.
Hanna M G BarrigaDepartment of Medical Biochemistry and Biophysics, Karolinska Institute, 171 77, Stockholm, Sweden.
Petter RanefallSciLifeLab BioImage Informatics Facility, and Department of Information Technology, Uppsala University, 751 05, Uppsala, Sweden.
Margaret N HolmeDepartment of Medical Biochemistry and Biophysics, Karolinska Institute, 171 77, Stockholm, Sweden.
Molly M StevensDepartment of Materials, Imperial College London, London, SW7 2AZ, UK. m.stevens@imperial.ac.uk.
Karolinska Institutet · SENIHR Imperial Biomedical Research Centre · GBUppsala University · SE

Funding

National Microscopy Infrastructure NMI VR-RFI 2019-00217Swedish Foundation of Strategic Research, Industrial Research Centre "FoRmulaEx" IRC15-0065
6 · The paper itself

Abstract

backgroundStochastic optical reconstruction microscopy (STORM), a super-resolution microscopy technique based on single-molecule localizations, has become popular to characterize sub-diffraction limit targets. However, due to lengthy image acquisition, STORM recordings are prone to sample drift. Existing cross-correlation or fiducial marker-based algorithms allow correcting the drift within each channel, but misalignment between channels remains due to interchannel drift accumulating during sequential channel acquisition. This is a major drawback in multi-color STORM, a technique of utmost importance for the characterization of various biological interactions.

resultsWe developed RegiSTORM, a software for reducing channel misalignment by accurately registering STORM channels utilizing fiducial markers in the sample. RegiSTORM identifies fiducials from the STORM localization data based on their non-blinking nature and uses them as landmarks for channel registration. We first demonstrated accurate registration on recordings of fiducials only, as evidenced by significantly reduced target registration error with all the tested channel combinations. Next, we validated the performance in a more practically relevant setup on cells multi-stained for tubulin. Finally, we showed that RegiSTORM successfully registers two-color STORM recordings of cargo-loaded lipid nanoparticles without fiducials, demonstrating the broader applicability of this software.

conclusionsThe developed RegiSTORM software was demonstrated to be able to accurately register multiple STORM channels and is freely available as open-source (MIT license) at https://github.com/oystein676/RegiSTORM.git and https://doi.org/10.5281/zenodo.5509861 (archived), and runs as a standalone executable (Windows) or via Python (Mac OS, Linux).

Indexed as

AlgorithmsMicroscopySoftwareImage analysis toolMulti-channelRegistrationSingle-molecule localization microscopySoftwareStochastic optical reconstruction microscopySuper-resolution microscopy

Identifiers

PMID37277712
PMCPMC10242778
OpenAlexW4379470141

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.