Evidence map›Paper›PMID 37276587›Full record

ArticleJournal of the American Society for Mass Spectrometry2023

Implementation of an Open-Source Multiplexing Ion Gate Control for High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS).

Cameron N Naylor, Brian H Clowers, Florian Schlottmann, Nic Solle, Stefan Zimmermann

Open access · hybridAbstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Cameron N NaylorInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany.ORCID 0000-0002-3426-0367
Brian H ClowersDepartment of Chemistry, Washington State University, Pullman, Washington 99164, United States.ORCID 0000-0002-5809-9379
Florian SchlottmannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany.ORCID 0000-0003-4824-6694
Nic SolleInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany.
Stefan ZimmermannInstitute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz University Hannover, 30167 Hannover Germany.ORCID 0000-0002-1725-6657
Leibniz University Hannover · DEWashington State University · US

Funding

Tractable Tandem Ion Mobility Technology using Structures for Lossless Ion Manipulations and PhotodissociationR01GM140129 · NIGMS · WASHINGTON STATE UNIVERSITY · PI CLOWERS, BRIAN · 2021 to 2024
$1.4M
NIGMS NIH HHS R01 GM140129
6 · The paper itself

Abstract

With ion mobility spectrometry increasingly used in mass spectrometry to enhance separation by increasing orthogonality, low ion throughput is a challenge for the drift-tube ion mobility experiment. The High Kinetic Energy Ion Mobility Spectrometer (HiKE-IMS) is no exception and routinely uses duty cycles of less than 0.1%. Multiplexing techniques such as Fourier transform and Hadamard transform represent two of the most common approaches used in the literature to improve ion throughput for the IMS experiment; these techniques promise increased duty cycles of up to 50% and an increased signal-to-noise ratio (SNR). With no instrument modifications required, we present the implementation of Hadamard Transform on the HiKE-IMS using a low cost, high-speed (600 MHz), open source microcontroller, a Teensy 4.1. Compared to signal average mode, 7- to 10-bit pseudorandom binary sequences resulted in increased analyte signal by over a factor of 3. However, the maximum SNR gain of 10 did not approach the theoretical

Indexed as

Hadamard transformion mobility spectrometrymultiplexingopen-source

Identifiers

PMID37276587
PMCPMC10326917
OpenAlexW4379473663

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.