Evidence map›Paper›PMID 37276437›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2023

Surgical Sealant with Integrated Shape-Morphing Dual Modality Ultrasound and Computed Tomography Sensors for Gastric Leak Detection.

Benjamin Suter, Alexandre H C Anthis, Anna-Katharina Zehnder, Victor Mergen, Jachym Rosendorf, Lukas R H Gerken, Andrea A Schlegel, Eva Korcakova, Vaclav Liska, Inge K Herrmann

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 4 countries.

Benjamin SuterNanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zürich, 8092, Switzerland.
Alexandre H C AnthisNanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zürich, 8092, Switzerland.
Anna-Katharina ZehnderNanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zürich, 8092, Switzerland.
Victor MergenDiagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Rämistrasse 100, Zürich, 8091, Switzerland.
Jachym RosendorfDepartment of Surgery, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 923/80, Pilsen, 32300, Czech Republic.
Lukas R H GerkenNanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zürich, 8092, Switzerland.
Andrea A SchlegelDepartment of Surgery and Transplantation, Swiss HPB Centre, University Hospital Zurich, Rämistrasse 100, Zurich, 8091, Switzerland.
Eva KorcakovaBiomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 1655/76, Pilsen, 32300, Czech Republic.
Vaclav LiskaDepartment of Surgery, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 923/80, Pilsen, 32300, Czech Republic.
Inge K HerrmannNanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zürich, 8092, Switzerland.ORCID 0000-0002-3018-6796
ETH Zurich · CHCharles University · CZFondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico · ITUniversity of Zurich · CH

Funding

Swiss National Science Foundation 181290
6 · The paper itself

Abstract

Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive, dual modality, electronic-free, leak sensor system integrable into surgical adhesive suture support materials is introduced. Leak sensors contain high atomic number carbonates embedded in a polyacrylamide matrix, that upon exposure to gastric fluid convert into gaseous carbon dioxide (CO

Indexed as

Artificial IntelligenceCarbon DioxideAnastomotic LeakHumansPostoperative ComplicationsTomography, X-Ray ComputedCarbon Dioxideadhesivesanastomotic leakmonitoringpostoperative complicationssensing

Identifiers

PMID37276437
PMCPMC10427398
OpenAlexW4379509286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.