Evidence map›Paper›PMID 37275600›Full record

ArticleGlobal journal on quality and safety in healthcare2020

Efficacy of Point-of-Care for INR Testing Compared to Standard Laboratory Methods at a Tertiary Care Hospital in Saudi Arabia.

Manzoor Bhat, Yacoub Abuzied, Zahra Fagih, Tariq Wani, Ismael Gawan, El Mae Andalay, Mohammed AlSheef

Open access · goldAbstract read
In one paragraph

Article in Global journal on quality and safety in healthcare, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.1field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Manzoor BhatPoint of Care Testing Department, Pathology and Clinical Laboratory Medicine, King Fahad Medical City, Riyadh, Saudi Arabia.
Yacoub AbuziedNursing Department, Rehabilitation Hospital, King Fahad Medical City, Riyadh, Saudi Arabia.
Zahra FagihPoint of Care Testing Department, Pathology and Clinical Laboratory Medicine, King Fahad Medical City, Riyadh, Saudi Arabia.
Tariq WaniResearch Center, King Fahad Medical City, Riyadh, Saudi Arabia.
Ismael GawanNursing Department, Outpatient Administration, King Fahad Medical City, Riyadh, Saudi Arabia.
El Mae AndalayNursing Department, Outpatient Administration, King Fahad Medical City, Riyadh, Saudi Arabia.
Mohammed AlSheefMedical Specialties Department, Main Hospital, King Fahad Medical City, Riyadh, Saudi Arabia.
King Fahd Medical City · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Regular testing of the international normalized ratio (INR) is essential for people taking vitamin K antagonists as part of anticoagulation therapy. This study was undertaken to ascertain the efficacy of point-of-care testing (POCT)-INR versus conventional core laboratory testing in terms of result adequacy, waiting-time reduction, and patient satisfaction enhancement at the thrombosis clinic of the outpatient Medical Specialties Department in King Fahad Medical City, Saudi Arabia. Methods: The study was conducted prospectively for 6 months (from June 2017 to December 2017) on 182 eligible participants out of 250 entitled patients who were attending the thrombosis clinic for warfarin dose adjustment and who fulfilled all the prerequisites for performing dual testing by fingerstick at the clinic and venipuncture by the core laboratory. The data-capturing template created on Microsoft Excel recorded turnaround times (TATs), clinical concordance of INR result variables by POCT, and laboratory methods. Individual patient experience was recorded to gauge satisfaction rate, and all the data were analyzed statistically. Results: Of 182 patients included in the study, overall good concord was observed between POCT whole blood and laboratory plasma INR results with median bias of 0.07 and 92.3% agreement using acceptability criteria for clinical concordance of Clinical Laboratory Standards Institute (CLSI) 14-A and International Standards Organization (ISO) 17593-2007, respectively. Marked improvement in terms of patient's time spent at the clinic was noted, with substantial reduction from 180 to ∼30 minutes ( Conclusions: Whole blood INR testing for warfarin dose adjustment with validated POCT devices is adequately comparable to the core laboratory results. It also simplifies workflow steps at the thrombosis clinic, enhancing patient experience and convenience via the immediate availability of results, a less invasive procedure, and a marked reduction in waiting time. However, caution is needed with regard to higher INR results (≥4.7), which call for core laboratory confirmation.

Indexed as

anticoagulation therapyinternational normalized ratiopoint-of-care devicethrombosisturnaround time

Identifiers

PMID37275600
PMCPMC10234087
OpenAlexW3047469868

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.