Biomechanical Characterization of a New Locking Loop Stitch for Graft Fixation versus Krackow Stitch.

Yasuo Itami, Orr Limpisvasti, Michelle H McGarry, Nilay A Patel, Charles C Lin, Thomas Dooney, Teruhisa Mihata, Masashi Neo, Thay Q Lee

Open access · diamondAbstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Yasuo ItamiOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0002-5381-2091
Orr LimpisvastiKerlan-Jobe Orthopaedic Clinic, Los Angeles, CA, USA.ORCID https://orcid.org/0000-0001-7193-3420
Michelle H McGarryOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0003-2266-2622
Nilay A PatelOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0001-8215-3729
Charles C LinOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0002-1491-6410
Thomas DooneyArthrex Inc., Naples, FL, USA.ORCID https://orcid.org/0000-0003-3669-2742
Teruhisa MihataOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0001-7306-5479
Masashi NeoDepartment of Orthopedic Surgery, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.ORCID https://orcid.org/0000-0001-9208-6419
Thay Q LeeOrthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, CA, USA.ORCID https://orcid.org/0000-0002-1639-0280
Orthopaedic Research Foundation · USArthrex (United States) · USCedars-Sinai Kerlan-Jobe Institute · USOsaka University of Pharmaceutical Sciences · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The purpose of this study was to quantify and compare the biomechanical characteristics of a new locking loop stitch (LLS), developed utilizing the concepts of both running locking stitch and needleless stitch, to the traditional Krackow stitch. Methods: The Krackow stitch with No.2 braided suture and the LLS with 1.3-mm augmented polyblend suture tape were compared biomechanically. The LLS was performed with single strand locking loops and wrapping suture around the tendon, resulting in half the needle penetrations through the graft compared to the Krackow stitch. Twenty bovine extensor tendons were divided randomly into two groups. The tendons were prepared to match equal thickness and cross-sectional area. Each suture-tendon was stitched and preloaded to 5 N for 60 seconds, cyclically loaded to 20 N, 40 N, and 60 N for 10 cycles each, and then loaded to failure. The deformation of the suture-tendon construct, stiffness, yield load, and ultimate load were measured. Results: The LLS had significantly less deformation of the suture-tendon construct at 100 N, 200 N, 300 N, and at ultimate load compared to the Krackow stitch (Krackow stitch and LLS at 100 N: 1.3 ± 0.1 mm and 1.0 ± 0.2 mm, Conclusions: The LLS had significantly smaller deformation of the suture-tendon construct compared to the Krackow stitch. The LLS may be a viable surgical alternative to the Krackow stitch for graft fixation when secure fixation is necessary.

Indexed as

Orthopedic ProceduresSuture TechniquesAnimalsBiomechanical PhenomenaCattleHumansSuturesTendonsTensile StrengthBiomechanicsGraftKrackowLocking loop

Identifiers

PMID37274497
PMCPMC10232308
OpenAlexW4362003581

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.