Evidence map›Paper›PMID 37271812›Full record

ArticleJournal of neuroengineering and rehabilitation2023

Spatiotemporal parameters for energy efficient kilohertz-frequency nerve block with low onset response.

Edgar Peña, Nicole A Pelot, Warren M Grill

Abstract read
In one paragraph

Article in Journal of neuroengineering and rehabilitation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Edgar PeñaDepartment of Biomedical Engineering, Duke University, Room 1427, Fitzpatrick CIEMAS, 101 Science Drive Campus Box 90281, Durham, NC, 27708, USA.
Nicole A PelotDepartment of Biomedical Engineering, Duke University, Room 1427, Fitzpatrick CIEMAS, 101 Science Drive Campus Box 90281, Durham, NC, 27708, USA.
Warren M GrillDepartment of Biomedical Engineering, Duke University, Room 1427, Fitzpatrick CIEMAS, 101 Science Drive Campus Box 90281, Durham, NC, 27708, USA. warren.grill@duke.edu.

Funding

Modeling Activation and Block of Autonomic Nerves for Analysis and DesignOT2OD025340 · OD · DUKE UNIVERSITY · PI GRILL, WARREN M. · 2017 to 2021
$5.9M
Optimized Electrical Block of Peripheral NervesR01NS126376 · NINDS · DUKE UNIVERSITY · PI Warren M. Grill · 2023 to 2026
$2.0M
NIH HHS OT2 OD025340NINDS NIH HHS R01 NS126376
6 · The paper itself

Abstract

backgroundElectrical nerve conduction block has great potential for treatment of disease through reversible and local inactivation of somatic and autonomic nerves. However, the relatively high energy requirements and the presence of undesired excitation at the onset of the kilohertz-frequency (KHF) signals used for block pose obstacles to effective translation. Frequency, electrode geometry, and waveform shape are known to influence block threshold and onset response, but available data provide a limited understanding of how to select these parameters to optimize nerve block.

methodsWe evaluated KHF nerve block in rat tibial nerve across frequencies (5-60 kHz), electrode geometries (monopolar, bipolar, and tripolar), and waveform shapes. We present a novel Fourier-based method for constructing composite signals that systematically sample the KHF waveform design space.

resultsThe lowest frequencies capable of blocking (5-16 kHz) were not the most energy-efficient among the tested frequencies. Further, bipolar cuffs required the largest current and power to block, monopolar cuffs required the lowest current, and both tripolar and monopolar cuffs required the lowest power. Tripolar cuffs produced the smallest onset response across frequencies. Composite signals comprised of a first harmonic sinusoid at fundamental frequency (f

conclusionsOur data provide novel information about block threshold and onset response at the boundary of frequencies that can block. Our results also show an interaction between spatial (cuff geometry) and temporal (frequency and waveform shape) parameters. Finally, while previous studies suggested that temporal parameters could reduce onset response only in exchange for increased block threshold (or vice versa), our results show that waveform shape influences KHF response in ways that can be exploited to reduce both energy and onset responses.

Indexed as

Nerve BlockNeural ConductionAnimalsConservation of Energy ResourcesElectric StimulationRatsTibial NerveEnergy efficiencyFrequency effectsKilohertz-frequency nerve blockOnset responseWaveform design

Identifiers

PMID37271812
PMCPMC10240787

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.