Evidence map›Paper›PMID 37268840›Full record

ArticleJournal of digital imaging2023

An AI-Based Image Quality Control Framework for Knee Radiographs.

Hongbiao Sun, Wenwen Wang, Fujin He, Duanrui Wang, Xiaoqing Liu, Shaochun Xu, Baolian Zhao, Qingchu Li, Xiang Wang, Qinling Jiang and 3 more

Abstract read
In one paragraph

Article in Journal of digital imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Hongbiao Sun *Department of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Wenwen Wang *Department of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Fujin He *Deepwise Artificial Intelligence Laboratory, Beijing, 100089, China.
Duanrui WangDeepwise Artificial Intelligence Laboratory, Beijing, 100089, China.
Xiaoqing LiuDeepwise Artificial Intelligence Laboratory, Beijing, 100089, China.
Shaochun XuDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Baolian ZhaoDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Qingchu LiDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Xiang WangDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Qinling JiangDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Rong ZhangDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China.
Shiyuan LiuDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China. radiology_cz@163.com.
Yi XiaoDepartment of Radiology, Shanghai Changzheng Hospital, Naval Medical University, No.415 Fengyang Road, Huangpu District, Shanghai, 200003, China. cz-xiaoyi@smmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Image quality control (QC) is crucial for the accurate diagnosis of knee diseases using radiographs. However, the manual QC process is subjective, labor intensive, and time-consuming. In this study, we aimed to develop an artificial intelligence (AI) model to automate the QC procedure typically performed by clinicians. We proposed an AI-based fully automatic QC model for knee radiographs using high-resolution net (HR-Net) to identify predefined key points in images. We then performed geometric calculations to transform the identified key points into three QC criteria, namely, anteroposterior (AP)/lateral (LAT) overlap ratios and LAT flexion angle. The proposed model was trained and validated using 2212 knee plain radiographs from 1208 patients and an additional 1572 knee radiographs from 753 patients collected from six external centers for further external validation. For the internal validation cohort, the proposed AI model and clinicians showed high intraclass consistency coefficients (ICCs) for AP/LAT fibular head overlap and LAT knee flexion angle of 0.952, 0.895, and 0.993, respectively. For the external validation cohort, the ICCs were also high, with values of 0.934, 0.856, and 0.991, respectively. There were no significant differences between the AI model and clinicians in any of the three QC criteria, and the AI model required significantly less measurement time than clinicians. The experimental results demonstrated that the AI model performed comparably to clinicians and required less time. Therefore, the proposed AI-based model has great potential as a convenient tool for clinical practice by automating the QC procedure for knee radiographs.

Indexed as

Artificial IntelligenceKnee JointHumansQuality ControlRadiographyArtificial intelligenceDeep learningImage quality controlKnee plain radiograph

Identifiers

PMID37268840
PMCPMC10501977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.