Evidence map›Paper›PMID 37265928›Full record

ArticleJGH open : an open access journal of gastroenterology and hepatology2023

Loop technique for guidewire manipulation during endoscopic ultrasound-guided hepaticogastrostomy.

Haruo Miwa, Kazuya Sugimori, Yuto Matsuoka, Kazuki Endo, Ritsuko Oishi, Masaki Nishimura, Yuichiro Tozuka, Takashi Kaneko, Kazushi Numata, Shin Maeda

Open access · goldAbstract read
In one paragraph

Article in JGH open : an open access journal of gastroenterology and hepatology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Haruo MiwaGastroenterological Center Yokohama City University Medical Center Yokohama Japan.ORCID https://orcid.org/0000-0001-6324-5433
Kazuya SugimoriGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Yuto MatsuokaGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Kazuki EndoGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Ritsuko OishiGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Masaki NishimuraGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Yuichiro TozukaGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Takashi KanekoGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Kazushi NumataGastroenterological Center Yokohama City University Medical Center Yokohama Japan.
Shin MaedaDivision of Gastroenterology Yokohama City University Graduate School of Medicine Yokohama Japan.ORCID https://orcid.org/0000-0002-0246-1594
Yokohama City University Medical Center · JPYokohama City University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aim: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is widely used in the management of biliary obstructions; however, literature on guidewire manipulation is lacking. This study aimed to assess the utility and optimal conditions of the loop technique for guidewire manipulation during EUS-HGS. Methods: Consecutive patients who underwent EUS-HGS between April 2015 and January 2022 were included in this study. Patient characteristics and procedural details were retrospectively analyzed. Guidewire manipulations were classified as conventional technique or loop technique, based on the shape of the guidewire tip. Results: A total of 52 patients (Median age: 73 years, 38 male and 14 female) underwent EUS-HGS. The median guidewire insertion time was 49 s and the median overall procedure time was 20.5 min. The initial guidewire direction was toward the peripheral side in 23 patients (44%). Technical success rate of the EUS-HGS was 100%. Twenty patients (38%) underwent the procedure using the loop technique and 32 (62%) with the conventional technique. In the logistic regression analysis, an angle between the bile duct and needle of >70° was independently associated with use of the loop technique (OR 9.84; 95% CI: 2.24-43.13; Conclusion: This study revealed the utility of the loop technique in EUS-HGS. This technique is recommended if the bile duct is punctured at an angle >70°.

Indexed as

biliary drainageEUS‐guided hepaticogastrostomyguidewire manipulationinterventional EUSloop technique

Identifiers

PMID37265928
PMCPMC10230106
OpenAlexW4365448907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.