Evidence map›Paper›PMID 37255023›Full record

ArticleJournal of synchrotron radiation2023

X-ray mirrors with sub-nanometre figure errors obtained by differential deposition of thin WSi

Patrice Bras, Christian Morawe, Sylvain Labouré, François Perrin, Amparo Vivo, Raymond Barrett

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Patrice BrasX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0001-9488-6778
Christian MoraweX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0002-9945-5587
Sylvain LabouréX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.
François PerrinX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.
Amparo VivoX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.
Raymond BarrettX-ray Optics Group, ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France.ORCID 0000-0002-2943-3905

Funding

H2020 Excellent Science 101004728
6 · The paper itself

Abstract

Differential deposition by DC magnetron sputtering was applied to correct for figure errors of X-ray mirrors to be deployed on low-emittance synchrotron beamlines. During the deposition process, the mirrors were moved in front of a beam-defining aperture and the required velocity profile was calculated using a deconvolution algorithm. The surface figure was characterized using conventional off-line visible-light metrology instrumentation (long trace profiler and Fizeau interferometer) before and after the deposition. WSi

Indexed as

AlgorithmsSynchrotronsRadiographyX-Raysdifferential depositionfigure correctionfilm stressFizeau stitchinglong trace profilermagnetron sputteringoff-line metrologysurface roughnessX-ray optics

Identifiers

PMID37255023
PMCPMC10325008

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials