Evidence map›Paper›PMID 37252625›Full record

ArticleAustralasian journal of ultrasound in medicine2023

Brief training in ultrasound equips novice clinicians to accurately and reliably measure jugular venous pressure in obese patients.

Nicholas A Pettit, Benjamin S Pedroja, Hsin Fang Li, Michael Sutcliffe

Open access · bronzeAbstract read
In one paragraph

Article in Australasian journal of ultrasound in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. POCUS is everywhere.Australasian journal of ultrasound in medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Nicholas A PettitDepartment of Internal Medicine Providence Portland Medical Center Portland Oregon USA.ORCID https://orcid.org/0000-0002-1949-1474
Benjamin S PedrojaDepartment of Internal Medicine Providence Portland Medical Center Portland Oregon USA.
Hsin Fang LiCenter for Cardiovascular Analytics, Research, and Data Science, Providence Heart Institute, Providence Research Network Portland Oregon USA.
Michael SutcliffeHealth Research Accelerator, Providence Research Network Portland Oregon USA.
Providence College · USProvidence Portland Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction/Purpose: Measurement of jugular venous pressure (JVP) by novice clinicians can be unreliable, particularly when evaluating obese patients. Measurement of JVP using ultrasound (uJVP) is simple to perform and provides accurate measurements. This study evaluated whether students and residents inexperienced with ultrasound could rapidly be taught to measure JVP using ultrasound in obese patients with the same accuracy as cardiologists measuring JVP via physical examination. Additionally, this study also evaluated the correlation between qualitative and quantitative JVP assessment. Methods: This prospective, blinded study compared uJVP measurements performed by novice clinicians after brief training to JVP measurements performed by cardiologists (cJVP) on physical examination. Association between uJVP and cJVP was assessed using linear correlation, agreement and bias were assessed using the Bland-Altman analysis and inter-rater reliability of uJVP was assessed using intraclass correlation coefficient (ICC). The association between qualitative and quantitative JVP assessment was assessed using linear correlation. Results: Novice clinicians (n = 16) obtained 34 measurements from 26 patients (mean BMI 35.5) and reported moderate-to-high confidence in all measurements. uJVP correlated well with cJVP (r = 0.73) with an average error of 0.06 cm. The estimated uJVP ICC was 0.83 (95% CI = 0.44, 0.96). Qualitative uJVP had only a moderate correlation (r = 0.63) to quantitative uJVP. Discussion: Novice clinicians often have difficulty assessing JVP on physical examination, particularly in obese patients. Our findings show a high degree of correlation between JVP measurements performed by novice clinicians using ultrasound compared with JVP measurements made by experienced cardiologists on physical examination. Furthermore, novice clinicians were able to be trained quickly, their measurements were determined to be accurate and precise and they expressed moderate-to-high confidence in their results. Conclusions: After brief training, novice clinicians were able to accurately assess JVP in obese patients as compared to measurements made by experienced cardiologists on physical examination. Results suggest that ultrasound may greatly improve novice clinicians' JVP assessment accuracy, particularly in obese patients.

Indexed as

heart failurejugular venous pressureJVPmedical educationPOCUSpoint of careuJVPultrasonography

Identifiers

PMID37252625
PMCPMC10225005
OpenAlexW4322739135

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.