ArticleEpilepsy & behavior reports2023
Artificial intelligence system, based on mjn-SERAS algorithm, for the early detection of seizures in patients with refractory focal epilepsy: A cross-sectional pilot study.
Article in Epilepsy & behavior reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 12 citations in OpenAlex.
- The use of AI in epilepsy and its applications for people with intellectual disabilities: commentary.Acta epileptologica · 2025Article
- Artificial Intelligence and Neuroscience: Transformative Synergies in Brain Research and Clinical Applications.Journal of clinical medicine · 2025Review
- Review
- Artificial Intelligence as A Complementary Tool for Clincal Decision-Making in Stroke and Epilepsy.Brain sciences · 2024Review
- Artificial intelligence in wearable seizure detection devices: current technologies and future directions.Frontiers in neurologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Around one-third of epilepsy patients develop drug-resistant seizures; early detection of seizures could help improve safety, reduce patient anxiety, increase independence, and enable acute treatment. In recent years, the use of artificial intelligence techniques and machine learning algorithms in different diseases, including epilepsy, has increased significantly. The main objective of this study is to determine whether the mjn-SERAS artificial intelligence algorithm developed by MJN Neuroserveis, can detect seizures early using patient-specific data to create a personalized mathematical model based on EEG training, defined as the programmed recognition of oncoming seizures before they are primarily initiated, usually within a period of a few minutes, in patients diagnosed of epilepsy. Retrospective, cross-sectional, observational, multicenter study to determine the sensitivity and specificity of the artificial intelligence algorithm. We searched the database of the Epilepsy Units of three Spanish medical centers and selected 50 patients evaluated between January 2017 and February 2021, diagnosed with refractory focal epilepsy who underwent video-EEG monitoring recordings between 3 and 5 days, a minimum of 3 seizures per patient, lasting more than 5 s and the interval between each seizure was greater than 1 h. Exclusion criteria included age <18 years, intracranial EEG monitoring, and severe psychiatric, neurological, or systemic disorders. The algorithm identified pre-ictal and interictal patterns from EEG data using our learning algorithm and was compared to a senior epileptologist's evaluation as a gold standard. Individual mathematical models of each patient were trained using this feature dataset. A total of 1963 h of 49 video-EEG recordings were reviewed, with an average of 39.26 h per patient. The video-EEG monitoring recorded 309 seizures as subsequently analyzed by the epileptologists. The mjn-SERAS algorithm was trained on 119 seizures and split testing was performed on 188 seizures. The statistical analysis includes the data from each model and reports 10 false negatives (no detection of episodes recorded by video-EEG) and 22 false positives (alert detected without clinical correlation or abnormal EEG signal within 30 min). Specifically, the automated mjn-SERAS AI algorithm achieved a sensitivity of 94.7% (95 %; CI 94.67-94.73), and an F-Score representing specificity of 92.2% (95 %; CI 92.17-92.23) compared to the reference performance represented by a mean (harmonic mean or average) and a positive predictive value of 91%, with a false positive rate of 0.55 per 24 h in the patient-independent model. This patient-specific AI algorithm for early seizure detection shows promising results in terms of sensitivity and false positive rate. Although the algorithm requires high computational requirements on specialized servers cloud for training and computing, its computational load in real-time is low, allowing its implementation on embedded devices for online seizure detection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.