Evidence map›Paper›PMID 37252251›Full record

ArticlePhysics and imaging in radiation oncology2023

Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac.

Daniel Nguyen, Rebeca Reinoso, Jad Farah, Sena Yossi, Fabrice Lorchel, Victor Passerat, Estelle Louet, Isabelle Pouchard, Mustapha Khodri, Nicolas Barbet

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
9.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Use of surface tracking recordings to identify pitfalls during surface-guided radiotherapy.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Daniel NguyenORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Rebeca ReinosoORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Jad FarahVision RT Ltd., Dove House, Arcadia Avenue, London N3 2JU, United Kingdom.
Sena YossiORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Fabrice LorchelORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Victor PasseratORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Estelle LouetORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Isabelle PouchardORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Mustapha KhodriORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Nicolas BarbetORLAM's Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France.
Vision RT (United Kingdom) · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods: Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a ± 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results: Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1° (range: 0.6°-1.1°) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions: Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.

Indexed as

Deep-inspiration breath-holdIntra-fraction controlLung stereotactic body radiotherapyRing-mounted SGRT system

Identifiers

PMID37252251
PMCPMC10213090
OpenAlexW4378745096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.