Evidence map›Paper›PMID 37251493›Full record

ArticleResearch and practice in thrombosis and haemostasis2023

Blood coagulation test abnormalities in trauma patients detected by sonorheometry: a retrospective cohort study.

Gary Duclos, Marie Fleury, Charlotte Grosdidier, Ines Lakbar, François Antonini, Bernard Lassale, Charlotte Arbelot, Pierre Albaladejo, Laurent Zieleskiewicz, Marc Leone

Abstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Gary DuclosService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Marie FleuryService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Charlotte GrosdidierService of Medical Biology, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Ines LakbarService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
François AntoniniService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Bernard LassaleFrench Establishment for Blood, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Charlotte ArbelotService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Pierre AlbaladejoDepartment of Anesthesiology and Critical Care, Grenoble Alpes University Hospital, Grenoble, France.
Laurent ZieleskiewiczService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.
Marc LeoneService of Anesthesia and Intensive Care, Hôpital Nord, Aix-Marseille Université, Marseille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Traumatic hemorrhage guidelines include point-of-care viscoelastic tests as a standard of care. Quantra (Hemosonics) is a device based on sonic estimation of elasticity via resonance (SEER) sonorheometry to assess whole blood clot formation. Objectives: Our study aimed to assess the ability of an early SEER evaluation to detect blood coagulation test abnormalities in trauma patients. Methods: We conducted an observational retrospective cohort study with data collected at hospital admission of consecutive multiple trauma patients from September 2020 to February 2022 at a regional level 1 trauma center. We performed a receiving operator characteristic curve analysis to determine the ability of the SEER device to detect blood coagulation test abnormalities. Four values on the SEER device were analyzed: clot formation time, clot stiffness (CS), platelet contribution to CS, and fibrinogen contribution to CS. Results: A total of 156 trauma patients were analyzed. The clot formation time value predicted an activated partial thromboplastin time ratio of >1.5 with an area under the curve (AUC) of 0.93 (95% CI, 0.86-0.99). The AUC of the CS value in detecting an international normalized ratio of prothrombin time of >1.5 was 0.87 (95% CI, 0.79-0.95). The AUC of fibrinogen contribution to CS to detect a fibrinogen concentration of <1.5 g/L was 0.87 (95% CI, 0.80-0.94). The AUC of platelet contribution to CS to detect a platelet concentration of <50 G/L was 0.99 (95% CI, 0.99-1.00). Conclusion: Our results suggest that the SEER device may be useful for the detection of blood coagulation test abnormalities at trauma admission.

Indexed as

blood coagulation testcritical carehemorrhagemultiple traumasthromboelastography

Identifiers

PMID37251493
PMCPMC10208882

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.