Evidence map›Paper›PMID 37250745›Full record

ArticleOrthopaedic journal of sports medicine2023

The "N+10 Rule" to Avoid Graft-Tunnel Mismatch in Bone-Patellar Tendon-Bone ACL Reconstruction Using Independent Femoral Tunnel Drilling.

Ryan M Graf, Scott E Dart, Ian S MacLean, Laurel A Barras, Thomas E Moran, Brian C Werner, F Winston Gwathmey, David R Diduch, Mark D Miller

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Ryan M GrafUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Scott E DartUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Ian S MacLeanUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Laurel A BarrasUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Thomas E MoranUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Brian C WernerUniversity of Virginia Health System, Charlottesville, Virginia, USA.
F Winston GwathmeyUniversity of Virginia Health System, Charlottesville, Virginia, USA.
David R DiduchUniversity of Virginia Health System, Charlottesville, Virginia, USA.
Mark D MillerUniversity of Virginia Health System, Charlottesville, Virginia, USA.
University of Virginia Health System · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Graft-tunnel mismatch (GTM) is a common problem in anterior cruciate ligament (ACL) reconstruction (ACLR) using bone-patellar tendon-bone (BPTB) grafts. Hypothesis: Application of the "N+10 rule" in endoscopic ACLR with BPTB grafts will result in acceptable tibial tunnel length (TTL), minimizing GTM. Study Design: Controlled laboratory study. Methods: Endoscopic BPTB ACLR was conducted on the paired knees of 10 cadaveric specimens using 2 independent femoral tunnel drilling techniques-accessory anteromedial portal and flexible reamer. The graft bone blocks were trimmed to 10 × 20 mm, and the intertendinous distance (represented by "N") between the bone blocks was measured. The N+10 rule was used to set the angle of the ACL tibial tunnel guide to the appropriate number of degrees for drilling. The amount of excursion or recession of the tibial bone plug in relation to the anterior tibial cortical aperture was measured in both flexion and extension. A GTM threshold of ±7.5 mm was set based on prior studies. Results: The mean BPTB ACL intertendinous distance was 47.5 ± 5.5 mm. The mean measured intra-articular distance was 27.2 ± 3 mm. Using the N+10 rule, the mean total (flexion plus extension) GTM was 4.3 ± 3.2 mm (GTM in flexion, 4.9 ± 3.6 mm; GTM in extension, 3.8 ± 3.5 mm). In 18 of 20 (90%) cadaveric knees, the mean total GTM fell within the ±7.5-mm threshold. When comparing the actual measured TTL to the calculated TTL, there was a mean difference of 5.4 ± 3.9 mm. When comparing femoral tunnel drilling techniques, the total GTM for the accessory anteromedial portal technique was 2.1 ± 3.7 mm, while the total GTM for the flexible reamer technique was 3.6 ± 5.4 mm ( Conclusion: The N+10 rule resulted in an acceptable mean GTM in both flexion and extension. The mean difference between the measured versus calculated TTL using the N+10 rule was also acceptable. Clinical Relevance: The N+10 rule is a simple and effective intraoperative strategy for achieving desired TTL regardless of patient-specific factors to avoid excessive GTM in endoscopic BPTB ACLR using independent femoral tunnel drilling.

Indexed as

anterior cruciate ligamentgraft-tunnel mismatchreconstructiontibial tunnel length

Identifiers

PMID37250745
PMCPMC10214051
OpenAlexW4378625545

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.