SynthesisEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2023
All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials.
Synthesis in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- Robotic-assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomized controlled trials.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Pooled it
- A theoretical bayesian decision tree model for prioritizing RA-TKA under constrained resources robotic-assisted versus conventional total knee arthroplasty.Journal of robotic surgery · 2026Article
- Article
- Mid-term outcomes of medial metal backed and all-polyethylene unicompartmental knee arthroplasty in obese patients: a retrospective propensity-matched analysis.Journal of orthopaedic surgery and research · 2024Article
- Enhancing the data capture of periprosthetic joint infections in the Danish Knee Arthroplasty Registry: validity assessment and incidence estimation.Acta orthopaedica · 2024Observational
- Letter to the Editor on "All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials".European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe design of tibial trays for total knee arthroplasty (TKA) has been a topic of research for several decades. Although all-polyethylene trays were developed to address issues such as osteolysis and to enhance the longevity of the prosthesis, as well as knee range of motion, metal-backed designs have remained the most commonly used type of prosthesis. This meta-analysis aimed to compare the clinical, radiological, and survival outcomes of both designs.
methodsFive databases were searched from inception until October 1, 2020, for randomized controlled trials (RCTs) that compared the outcomes of all-polyethylene and metal-backed tibial components in TKA. The outcomes of interest included range of motion, knee society score, stairs climbing scores, radiostereographic analysis, survivorship and complication. This review was conducted in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Risk of bias was assessed using the Newcastle-Ottawa tool.
resultsA total of 14 RCTs with 1367 TKA were included with a mean age of - years and - years for all-polyethylene and metal-backed tibial components groups, respectively. All-polyethylene group demonstrated statistically significant differences in five-year survivorship (OR 0.27; 95% CI 0.10-0.75; p value 0.01) and stairs climbing score (OR - 2.07; 95% CI - 3.27-0.87; p value 0.0007) when compared to the metal-backed group. The metal-backed design was significantly more radiographically stable in anterior-posterior, varus-valgus, and internal-external rotations at the 2-year follow-up compared to all-polyethylene tibias (OR - 0.09; 95% CI - 0.16 to - 0.02; p value 0.02) as per the pooled radiostereographic analysis. However, ten-year survivorship (OR 0.92; 95% CI 0.53-1.60; p value 0.78), range of motion (OR - 0.57; 95% CI - 2.00-0.85, p value 0.43), knee society scores (OR 1.38; 95% CI - 0.47-3.23, p value 0.14), and complications (OR 0.83; 95% CI 0.5-1.39, p value 0.48) were comparable between both groups.
conclusionsWhile this meta-analysis suggests that all-polyethylene tibial components in total knee arthroplasty may offer advantages over metal-backed components in terms of five-year survivorship, and stairs climbing score, this finding should be considered in the context of potential confounding factors. Nonetheless, based on the results, the all-polyethylene implant should be considered a viable choice for primary knee replacement. LEVEL OF EVIDENCE: I.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.